OPERATION
B-1
Read and understand this entire section before oper-
ating your Mobiflex 200-M.
SAFETY INSTRUCTIONS
Do not attempt to use this equipment until you have
thoroughly read all operating and maintenance man-
uals supplied with your equipment and any related
welding machine it will be used with. They include
important safety precautions, operating and mainte-
nance instructions and parts lists.
ELECTRIC SHOCK can kill.
•Do not touch electrically live parts such
as output terminals or internal wiring.
•Insulate yourself from the work and
ground.
•Always wear dry insulating gloves.
------------------------------------------------------------------------
WELDING SPARKS can cause fire or
explosion.
•Keep flammable material away.
•Do not weld upon containers which
have held combustibles.
------------------------------------------------------------------------
ARC RAYS can burn.
•Wear eye, ear and body protection.
------------------------------------------------------------------------
FUMES AND GASES
can be dangerous.
• Although the removal of the particu-
late matter from welding smoke may
reduce the ventilation requirement,
concentrations of the clear exhausted
fumes and gases may still be haz-
ardous to health. Avoid breathing
concentrations of these fumes and
gases. Use adequate ventilation
when welding. See ANSI Z49.1,
"Safety in Welding and Cutting", pub-
lished by the American Welding
Society.
------------------------------------------------------------------------
Only qualified personnel should operate this equip-
ment.
ADDITIONAL SAFETY PRECAUTIONS
Always operate this equipment with the filter and arm
installed and all covers in place as these provide max-
imum protection from moving parts and insure proper
vacuum operation and cooling air flow.
OPERATING INSTRUCTIONS
Connect the Mobiflex 200-M to 120 VAC input power.
Leave the Start/Stop Switch on the Mobiflex base unit
in the “Start” position to control the Mobiflex 200-M
and Work Lamp from the Hood-mounted switch.
Refer to Figure 10:
A. Switch with Lamp Symbol - Operates Lamp.
B. Switch with 0/I- Operates Mobiflex 200-M.
For optimum fume-capture, position hood within
10-15 inches (250-400mm) of the arc.
If using the Automatic Start/Stop Arc Sensor, leave
the 0/I switch in the 0 (off) position (the Start/Stop
switch on the Mobiflex 200-M must be in the “Start”
position). When the sensor detects an arc, it will start
the Mobiflex 200-M automatically. When it no longer
detects the arc, the sensor will shut down the Mobiflex
after 20 seconds.
LAMP OPTIONS FOR MOBIFLEX 200-M
WARNING
I
O
A
B
Fig. 10