SAFETY PRECAUTIONS

ROUTINE MAINTENANCE

Routine maintenance consists of periodically blowing
out the machine, using a low pressure airstream, to
remove accumulated dust and dirt from inside the
feeder.

PERIODIC MAINTENANCE

Replace the drive rolls and inner wire guide when

they are worn.

Replace the pig tail if the insulation is cut, abraded

or damaged.

CALIBRATION SPECIFICATION

All calibration is factory set on the LN-15.

To verify the wire feed speed:

Assemble a .045 (1.2mm) drive roll kit into the LN-

15.

Load a spool of .045 (1.2mm) electrode and thread

the electrode through the wire drive.

Adjust the wire feed speed to 300 in/min

(7.62m/min).

Press the COLD FEED switch and measure the

actual wire feed speed with a calibrated wire feed
speed tachometer.

The measured wire feed speed should be within 2%

of the set value.

To verify the voltage display:

Set the welding power source and LN-15 to a CV

procedure that gives steady "spray" transfer in the
arc.

While a weld is being made, measure the voltage

from the feed plate to work.

The displayed voltage on the LN-15 should be with-

in 2% of the measured value.