MAINTENANCE
D-1
LN-15 ACROSS THE ARC MODEL
ELECTRIC SHOCK can kill.
•
Do not operate with covers
removed.
•
Turn off power source before
installing or servicing.
•
Do not touch electrically hot
parts.
•
Turn the input power to the welding power
source off at the fuse box before working in the
terminal strip.
•
Only qualified personnel should install, use or
service this equipment.
WARNING
SAFETY PRECAUTIONS
ROUTINE MAINTENANCE
Routine maintenance consists of periodically blowing
out the machine, using a low pressure airstream, to
remove accumulated dust and dirt from inside the
feeder.
PERIODIC MAINTENANCE
•
Replace the drive rolls and inner wire guide when
they are worn.
•
Replace the pig tail if the insulation is cut, abraded
or damaged.
CALIBRATION SPECIFICATION
All calibration is factory set on the LN-15.
To verify the wire feed speed:
•
Assemble a .045 (1.2mm) drive roll kit into the LN-
15.
•
Load a spool of .045 (1.2mm) electrode and thread
the electrode through the wire drive.
•
Adjust the wire feed speed to 300 in/min
(7.62m/min).
•
Press the COLD FEED switch and measure the
actual wire feed speed with a calibrated wire feed
speed tachometer.
•
The measured wire feed speed should be within 2%
of the set value.
To verify the voltage display:
•
Set the welding power source and LN-15 to a CV
procedure that gives steady "spray" transfer in the
arc.
•
While a weld is being made, measure the voltage
from the feed plate to work.
•
The displayed voltage on the LN-15 should be with-