LN-15 ACROSS THE ARC MODEL

Rotate the WFS knob until the desired parameter is
displayed.

CV/CC Mode:

WFS Units:

2. Activate and release the GAS PURGE switch to

select the parameter. The present value will then
display in the right hand side of the display.
Example:

3. Rotate the WFS knob to change the parameter set-

ting.

CV/CC Mode:

"CU" for Constant Voltage power sources

"CC" for Constant Current power sources

WFS Units:

"US" for in/min

"Eur" for mm/min

4. Press the GAS PURGE switch to save the setting.

The LN-15 will then return to the original "Press
Spin" mode in step 1.

5. To exit the "Press Spin" set-up mode, turn off power

to the LN-15, or simply wait 15 seconds and the