beautypg.com

Installation, Technical specifications - invertec v100-s – Lincoln Electric IM585 INVERTEC V-130-S User Manual

Page 8

background image

-20°C to +40°C

-25°C to +55°C

A-1

INSTALLATION

INVERTEC® V100-S & V130-S

A-1

Height

Width

Depth

Weight

10.0 in.

5.4 in.

13.8 in.

11.0 lbs.

254 mm

138 mm

351 mm

5.0 Kg

PHYSICAL DIMENSIONS

INPUT

Input Current

Voltage

(2)

at Rated Output

Hertz

32A @ 100A OUTPUT

115V

25A @ 85A OUTPUT

50/60 Hz

20A @ 70A OUTPUT

Volts at

Duty Cycle

(1)

Amps

Rated Amps

15% Duty Cycle

100

24

20% Duty Cycle

85 (20 Amp Circuit)

23.5

20% Duty Cycle

70 (15 Amp Circuit)

23

Welding

Maximum Open

Current Range

Circuit Voltage

8-100 Amps

67 VDC

INPUT

RECOMMENDED INPUT CABLE AND FUSE SIZES

OUTPUT

FUSE (SUPERLAG)

INPUT

POWER

EXTENSION

EXTENSION

CURRENT OR BREAKER SIZE CURRENT

CORD

CORD

CORD

RATING

(up to 50 feet)

(more than 50 feet)

100A

30A

32A

30 Amp, 125V,

Three Conductor

Three Conductor

Three-prong plug

#10 AWG (5.2 mm

2

) #8 AWG (8.2 mm

2

)

(NEMA Type 5-30P)

or larger

or larger

85A

25A

25A

20Amp, 125V,

Three Conductor

Three Conductor

Three-prong plug

#12 AWG (3.3 mm

2

) #10 AWG (5.2 mm

2

)

(NEMA Type 5-20P)

or larger

or larger

70A

20A

20A

15 Amp, 125V,

Three Conductor

Three Conductor

Three-prong plug

#14 AWG (2.0 mm

2

) #12 AWG (3.3 mm

2

)

(NEMA Type 5-15P)

or larger

or larger

SINGLE PHASE

OPERATING TEMPERATURE

STORAGE TEMPERATURE

RATED OUTPUT

(1)

Based on a 10 min. period.

(2) Input voltage must be within ±10% of rated value.

Technical Specifications - Invertec V100-S

OUTPUT

This manual is related to the following products: