Installation, Technical specifications - invertec v100-s – Lincoln Electric IM585 INVERTEC V-130-S User Manual
Page 8
-20°C to +40°C
-25°C to +55°C
A-1
INSTALLATION
INVERTEC® V100-S & V130-S
A-1
Height
Width
Depth
Weight
10.0 in.
5.4 in.
13.8 in.
11.0 lbs.
254 mm
138 mm
351 mm
5.0 Kg
PHYSICAL DIMENSIONS
INPUT
Input Current
Voltage
(2)
at Rated Output
Hertz
32A @ 100A OUTPUT
115V
25A @ 85A OUTPUT
50/60 Hz
20A @ 70A OUTPUT
Volts at
Duty Cycle
(1)
Amps
Rated Amps
15% Duty Cycle
100
24
20% Duty Cycle
85 (20 Amp Circuit)
23.5
20% Duty Cycle
70 (15 Amp Circuit)
23
Welding
Maximum Open
Current Range
Circuit Voltage
8-100 Amps
67 VDC
INPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
OUTPUT
FUSE (SUPERLAG)
INPUT
POWER
EXTENSION
EXTENSION
CURRENT OR BREAKER SIZE CURRENT
CORD
CORD
CORD
RATING
(up to 50 feet)
(more than 50 feet)
100A
30A
32A
30 Amp, 125V,
Three Conductor
Three Conductor
Three-prong plug
#10 AWG (5.2 mm
2
) #8 AWG (8.2 mm
2
)
(NEMA Type 5-30P)
or larger
or larger
85A
25A
25A
20Amp, 125V,
Three Conductor
Three Conductor
Three-prong plug
#12 AWG (3.3 mm
2
) #10 AWG (5.2 mm
2
)
(NEMA Type 5-20P)
or larger
or larger
70A
20A
20A
15 Amp, 125V,
Three Conductor
Three Conductor
Three-prong plug
#14 AWG (2.0 mm
2
) #12 AWG (3.3 mm
2
)
(NEMA Type 5-15P)
or larger
or larger
SINGLE PHASE
OPERATING TEMPERATURE
STORAGE TEMPERATURE
RATED OUTPUT
(1)
Based on a 10 min. period.
(2) Input voltage must be within ±10% of rated value.
Technical Specifications - Invertec V100-S
OUTPUT