The machine is dead - no output -
no fan.
No output but the fan operates nor-
mally.
Output turns on momentarily, then
switches off.
No output - Main input fuses open,
indicating excessive current draw.
1. The input power switch must be
in the ON position.
2. Make sure the input voltage is
correct for the machine.
1. The machine may be overheated.
Check the thermal indicator light.
Wait for the machine to cool and
the thermostats to reset.
1. Check the input voltage. Make
sure the input voltage is correct
for the machine.
1. Inspect input leads for possible
shorts or grounds or mis-connec-
tions.
2. Install new fuses and reapply
power. If fuses open again, con-
sult a Lincoln Authorized Field
Service Facility.
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.