PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENTS(S)

RECOMMENDED

COURSE OF ACTION

Poor welding, weld settings drift, or
output power is low.

Poor stick electrode welding
performance. The arc pops out.

1. Make sure the machine settings

are correct for the weld process
being used.

2. Make sure the input voltage is

correct for the machine.

1. Check for loose or faulty welding

cables.

2. Is the electrode DRY? Try weld-

ing with another electrode from a
different container. Make sure
you have the correct electrode for
the application.

3. Make sure the machine settings

are correct for the weld process
being used.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized Field
Service Facility.