Installation, Technical specifications – dc-1000 – Lincoln Electric IM420 IDEALARC DC-1000 User Manual
Page 8

A-1
INSTALLATION
IDEALARC® DC-1000
A-1
60% Duty Cycle
215/108
86
215/124/108
124/94
113
TECHNICAL SPECIFICATIONS – DC-1000
Volts at Rated Amperes
44
44
44
Auxiliary Power
See the OPERATION section
for Auxiliary Power
information by model
Amps
1000
1140
1250
Maximum Open Circuit Voltage
75V for 60 HZ models
72V for 50/60 HZ models
Duty Cycle
100% Duty Cycle
60% Duty Cycle
50% Duty Cycle
Output Range
150A/16V-1300A/46V
INPUT - THREE PHASE ONLY
OUTPUT
1Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.
RECOMMENDED INPUT WIRE AND FUSE SIZES
Standard
Voltage
230/460/60
575/60
220/380/440/50/60
380/500/50/60
415/50/60
100% Duty Cycle
193/96.5
77.2
193/112/96.5
112/85
102
50% Duty Cycle
230/115
92
230/133/115
133/101
121
Input Current at Rated Output
RATED OUTPUT
INPUT
VOLTAGE /
FREQUENCY
230
460
575
220
380
415
440
500
TYPE 75°C
(SUPER LAG)
OR BREAKER
SIZE (AMPS)
1
300 Amp
150 Amp
125 Amp
300 Amp
175 Amp
150 Amp
150 Amp
125 Amp
TYPE 75°C
GROUND WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIZES
4 (21)
6 (14)
6 (14)
4 (21)
6 (14)
6 (14)
6 (14)
6 (14)
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG(IEC-MM
2
) SIZES
30°C (86°F) Ambient
000 (85)
3 (27)
4 (21)
000 (85)
2 (34)
2 (34)
3 (27)
4 (21)
INPUT AMPERE
RATING ON
NAMEPLATE
193
96.5
77.2
193
112
102
96.5
85
HERTZ
60
60
60
50/60
50/60
50/60
50/60
50/60
PHYSICAL DIMENSIONS
HEIGHT
30.75 in
781 mm
WIDTH
22.25 in
567 mm
DEPTH
39.0 in
991 mm
WEIGHT
821 lbs.
372 kg.