F-6

DIAGRAMS

F-6

DC-600 RED-D-ARC

A

bove diagram shows electrode connected positive.

To change polarity,

turn power off, reverse the electrode and work leads at the power

NEGATI

V

E

POSITI

V

E

32 31 2 4

GND

21

N

.A

.

N

.D

.

ELECTRODE

CABLE

TO

WORK

POWER

SOURCE

Only qualified persons should install, use or

service this machine.

Do not operate with covers removed.

Disconnect power source before

servicing.

Do not touch electrically live parts.

CONTROL

BO

X

21

FOR

CONTROL

CABLE

WITH

14

PIN

MS-T

Y

PE

PLUG

CONNECTOR

OR

FOR

CONTROL

CABLE

WITH

TERMINAL

STRIP

LEAD

CONNECTORS

CONTROL

CABLE

S22

978

N

.B

. &

N

.C

.

14-PIN

RECEPTACLE

75

76

77

remote voltage sensing work lead may be ordered for this purpose.

If lead #

21

is to be connected to

the terminal strip,

connect to the #

21

terminal that matches

work polarity.

This

connection must be changed whenever the

electrode polarity is

changed.

N

.A

.

W

elding cables must be of proper capacity for the current and

duty cycle of immediate and future applications.

C

onnect it directly to the work piece keeping it electrically

separate form the welding work lead circuit and connection.

For

convenience, this extended #

21

lead should be taped to the

welding work lead.

(If the length of work lead circuit is

short, and connections can be expected to be reliable, then

control cable lead #

21

does not need to be extended and can be

directly connected to terminal #

21

on the terminal strip.

N

ote

that this is not the preferred connection because it adds error

N

.D

.

C

onnect the control cable ground lead to the frame terminal

marked near the power source terminal strip.

The power

source grounding terminal

(marked and located near the power

source input power connections

) must be properly connected to

electrical ground per the power source operating manual.

to the wire feeder voltmeter reading.

)

N

.F

.

source.

Reverse the leads on the back of the ammeter and voltmeter

in the automatic control box.

Also refer to note

N.

F.

TO

AUTOMATIC

E

Q

UIPMENT

TO

AUTOMATIC

CONTROL

CABLE

physically suitable for the installation.

A

n

S16586-

[LENGTH

]

41

423

1

32

75

76

77

N

.F

.

21

-

21

+

REMOTE

V

OLTAGE

SENSING

LEAD

N

.C

.

Tape up bolted connection if lead #

21

is extended.

N

.E

.

If a variable voltage board is present in the automatic controls,

the jumper lead on the VV board must be connected to pin "

L" to

permit the inch down button to operate.

This jumper, however,

will disable the cold starting/autostop feature of the automatic

controls, permitting only hot starting techniques to be used.

or from

14-

pin receptacle using #

14

AWG

or larger insulated wire

N

.B

.

E

xtend lead #

21

from control cable with terminal strip connectors

10

-3

0-

98F

N

.G

.

Illustration does not necessarily represent actual position of

manual for more information.

N

.G

.

CONNECTION OF NA-3, LT-5 OR LT-7 TO THE CV-655, DC-655 OR DC-600 POWER SOURCE

appropriate output studs.

R

efer to power source operating

For proper setting of switches on power source,

see power source operating manual.