Weight

522 lbs.

(237 kg.)

INPUT - THREE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

PHYSICAL DIMENSIONS

Standard Voltage

Duty Cycle

100%

60%
50%

Mode

Constant Current

Constant Voltage

Auxiliary Power

115 VAC, 8 Amps

Current

Range

90 to 850 Amps
70 to 850 Amps

Input Voltage /

Frequency

Fuse

(Super Lag)

or Breaker Size

Input Ampere

Rating on

Nameplate

2 (35mm

2

)

2 (35mm

2

)

6 (16mm

2

)

6 (16mm

2

)

6 (16mm

2

)

6 (16 mm

2

)

6 (16 mm

2

)

8 (10 mm

2

)

8 (10 mm

2

)

8 (10 mm

2

)

208/60
230/60
416/60
460/60
575/60

175
175
100

90
80

125
113

63
57
45

Type 75

o

C

Copper Wire in

Conduit AWG

(IEC) Sizes

Type 75

o

C

Copper Ground

Wire in Conduit

AWG (IEC) Sizes

Depth

39.0 in.

(988 mm.)

Width

22.25 in.

(567 mm.)

Height

30.75 in.

(781 mm.)

Maximum Open

Circuit Voltage

72 VDC
55 VDC

AMPS

600
680
750

Volts at Rated Amps

44
44
44

Input Current at Rated Output

208/230/416/460/575/3/60

125/113/63/57/45