DataComm 45-0031-WH Recessed Low Voltage Media Plate with Duplex Receptacle User Manual
Page 4
Installation / Instruction Sheet 45-0041-WH (Continued)
Remember in the event your surge unit alarm sounds, simply remove the
replaceable SurgeBloc
®
. The receptacle still functions as a normal duplex
receptacle without surge protection. The Replacement SurgeBloc
®
module #1209 made by Cooper Wiring Devices can be ordered through a
DataComm Electronics distributor, your local electrical distributor or
contact Cooper Wiring Devices’ Sales Department at 800.441.3177 or
45-31 Court Square, Long Island, NY 11101.
WARNING
DataComm Electronics’ products shall be installed and used only as indicated in DataComm Electronics’ product instruction
sheets.
Instruction sheets are available online at www.datacommelectronics.com.
CAUTION
For shock protection, this device must be properly grounded.
Use copper wire only with this device.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.
Follow all warnings and instructions marked on the product.
Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near
a swimming pool.
SAVE THESE INSTRUCTIONS.
Surge Suppressor Specifications
Clamping Response Time: 1 Nanosecond
2-Pole 3-Wire
Grounding
60 Hz Receptacle
1875W
Total Maximum
Surge Dissipation
Maximum Surge
Current
Peak Suppression
Voltage
Surge Protection
Replacement
Module
15A-125V
1875W
340 Joules
12,000 Amps
1,000 Volts
Hot/Neutral,
Hot/Ground,
Neutral/Ground
# 1209
ONLY LICENSED PROFESSIONALS SHOULD INSTALL THIS PRODUCT
Removing the SurgeBloc
®
Module
888.223.7977
www.datacommelectronics.com
1/5/11 Rev. 2
Page 2 of 3