Installation Instructions for the Bottom Cable Plate with Straight Blade Inlet:













































WARNING

DataComm Electronics’ products shall be installed and used only as indicated in DataComm Electronics’ product instruction sheets.
Instruction sheets are available online at www.datacommelectronics.com.


CAUTION
For shock protection, this device must be properly grounded.
Use copper wire only with this device.


IMPORTANT INSTRUCTIONS

Read and understand all instructions.

Follow all warnings and instructions marked on the product.

Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a

swimming

pool.

SAVE THESE INSTRUCTIONS.









This product is patent protected by U.S. Patent numbers D553475, D554475 and 7390964.
RoHS Compliant.

888.223.7977

www.datacommelectronics.com

Figure 10
Important:
Before installing the Plate with Straight Blade Inlet into the template opening, make sure to pull your low voltage
cables through the low voltage cable opening. If you have more than 4 cables you can remove the flexible plate that seals the
low voltage cable opening. This allows for more cables to be pulled through the opening.

After you have pulled your low voltage or A/V cables through the low voltage opening: Start with the side of the Plate
with Straight Blade Inlet and slowly slide the plate into the opening. Swing the right side of the plate into position until the entire
plate is flush with the wall. Now screw down the screws with wings; these wings fasten tightly against the back of the drywall.

Figure 11
Your new 45-0024-WH Recessed Pro Power Kit with Duplex Receptacle and Straight Blade Inlet is now installed and ready for
the flat panel TV mount to be installed. Install your flat panel TV mounting bracket per the flat panel TV bracket manufacturer’s
instruction.

Installation / Instruction Sheet 45-0024-WH (Continued)

Fig. 8

Figure 8
Wire the Cable Plate with Straight Blade Inlet to the 12/2 w/ground or 14/2 w/ground UL approved electrical building wire.
Connect the hot line (black) wire to the black wire and the neutral (white) wire to the white wire on the straight blade inlet. Be
sure to connect the grounding (green) or bare grounding wire to the green wire on the straight blade inlet. Make sure the three
wire nuts are fastened tightly.

Fig. 9

Figure 9
Now use the four screws provided to secure the electrical outlet box to the mounting studs on the backside of the Cable Plate
with Straight Blade Inlet.

Fig. 10

Fig. 11

Fig. 12

Figure 12
Hang your flat panel TV on the mounting bracket and plug your TV into the top Cable Plate with Duplex Receptacle. Now plug
your cord set into bottom Cable Plate with Straight Blade Inlet. Then plug the male end of the cord set into a nearby wall
receptacle.