beautypg.com

Condec DPDG User Manual

Page 9

background image

8

Over Pressure Protection:
Ranges from 15 PSI to 500 PSI:

3X input pressure range

1,000, 3,000, and 5,000 PSI ranges:

2X input pressure range

10,000 PSI:

1.5X input pressure range

Temperature Compensation
0°C to +50°C (32°F to +122°F) to rated accuracy
Note: For temperatures from –10 °C to 0 °C and 50 °C to 55 °C add

.005% F.S./°C

Standard Engineering Units
PSI, Bar, kg/cm2, inH

2

O (4°C, 20°C or 60°F),

ftH

2

O (4°C, 20°C or 60°F), cmH

2

O (4 °C and 20 °C), mH

2

O (4°C and

20°C), KPa, mBAR, inHg, mmHg, Torr
One custom unit (user programmable)

Media Compatibility
Liquids and gases compatible with 316 stainless steel

Environmental
Operating Temperature -10 °C to +55 °C
Storage -20 °C to +70 °C (-4 °F to +158 °F)
Humidity 10% to 95% RH Non-condensing
Pollution Degree II

Mechanical
Dimensions 4.5” (diameter) x 2.2” (depth) x 5” (height)
Pressure Connection: ¼” NPT Male
Housing: Stainless steel, meets NEMA 4/IP65

Display
5-1/2 Digits, 0.65” (16.53 mm) high
20-Segment bar graph, 0 to 100%

Power
Battery three (3), size AA alkaline batteries, optional 24 VDC power.
Battery Life 1,500 hours without backlight
2,000 hours at slow sample rate
Low Battery Indicator icon is displayed near the end of battery life