Ided in, Table 1, Power supply specifications – Brocade 6520 Hardware Reference Manual User Manual
Page 19: Are met
![background image](/manuals/361679/19/background.png)
Brocade 6520 Hardware Reference Manual
7
53-1002705-02
Installation and safety considerations
2
, and
illustrate the power consumption of the switch as measured at idle,
maximum, and typical states respectively.
TABLE 1
Power supply specifications
Specification Value
Input voltage
Range: 90-264 VAC Auto-volt, Nominal: 100-240 VAC, ~12.0A - 5.0A;
switch autosenses input voltage.
Start-up: 80-87 VAC, Turn-off: 85-75 VAC
Input frequency
Range: 47-63 Hz; Nominal: 50-60 Hz.
Inrush current
Limited to 40A peak @ 240 VAC during cold start-up at 25ºC ambient
Input line protection
Both AC lines are fused.
Maximum power supply output (each)
1080 watts @ 12V DC
TABLE 2
Power consumption - idle
IDLE, no Optics, C3 not initialzed, Fan Speed normal(3030RPM),Room Temp
AC Voltage Input Current (Amp) Input Watts
1 PSU
Power Factor
BTU's/hr
1 PSU
Input Watts
2 PSU's
BTU's/hr
2PSU
1 PSU
2 PSU
AC Measured 1 PSU
2 PSU
AC Measured
100 VAC
1.78
1.85
179
0.998
0.993
610.94132
183
624.59364
120 VAC
1.49
1.59
178
0.996
0.968
607.52824
183
624.1764
200 VAC
0.92
1.08
174
0.949
0.847
593.87592
182
620.7656
240 VAC
0.79
1.04
174
0.917
0.739
593.87592
181
617.3548
TABLE 3
Power consumption - maximum
MAX: All ports configured with ELOAD, Traffic Running (mode 11), Fan Speed Max (8190 RPM),Room Temp
AC Voltage Input Current (Amp) Input Watts
1 PSU
Power Factor
BTU's/hr
1 PSU
Input Watts
2 PSU's
BTU's/hr
2PSU
1 PSU
2 PSU
AC Measured 1 PSU
2 PSU
AC Measured
100 VAC
4.67
4.67
464
0.995
0.995
1582.6112
464
1582.6112
120 VAC
3.86
3.87
462
0.997
0.997
1575.7896
463
1579.2004
200 VAC
2.28
2.34
455
0.998
0.977
1551.914
457
1558.7356
240 VAC
1.92
1.99
453
0.998
0.953
1545.0924
456
1555.3248
TABLE 4
Power consumption - typical
Typical: All ports configured with 16G Avago optics, Traffic Running (mode 11), Fan Speed Nominal(3030 RPM), Room Temp
AC Voltage Input Current (Amp) Input Watts
1 PSU
Power Factor
BTU's/hr
1 PSU
Input Watts
2 PSU's
BTU's/hr
2PSU
1 PSU
2 PSU
AC Measured 1 PSU
2 PSU
AC Measured
100 VAC
3.96
3.97
394
0.998
0.996
1343.8552
395
1347.266
120 VAC
3.26
3.29
391
0.997
0.995
1333.6228
394
1343.8552
200 VAC
1.94
2.02
387
0.997
0.963
1319.9796
390
1330.212
240 VAC
1.74
1.62
385
0.989
0.929
1313.158
388
1323.3904