beautypg.com

Battery installation, Illuminated reticle – NcSTAR VEVOFP62450G User Manual

Page 6

background image

6

It is important to remember that many factors can affect the accuracy of your scopes zero including

temperature, humidity, elevation, distance, angle, and other conditions. Changing ammunition brands can
affect accuracy as well.

Battery Installation

Your Illuminated Model EVO Series Scope comes with a battery pre-installed from

the factory. To replace the battery follow these simple steps:

1. The Battery Compartment is located within the Rheostat Dial on top of the Ocular

Lens Housing.

2. On top of the Rheostat Dial you will notice a thin Battery Cap. To remove this cap

grasp it firmly with one hand, and twist the cap counter-clockwise

()

while holding

the lower Rheostat Dial firmly in place with the other hand.

3. Remove the old battery, and dispose of it properly. Replace it with a new 3 volt

Lithium Battery Type CR2032 only. Place the Battery into the Battery compartment
with the Positive “+” terminal facing out. Place the battery cap back on top of the
Rheostat Dial. Twist the battery cap clockwise

()

back onto the Rheostat Dial and

hand tighten. Avoid using tools (such as pliers) to perform this procedure as this may
cause damage to the unit.

Illuminated Reticle

Your EVO Series Scope is equipped with a Glass Etched Reticle that can be illuminated in 2

different colors (Blue or Green) for use when exterior lighting conditions are less than optimal. A Glass
Etched Reticle has a finer detailed reticle and is more durable than your typical wire reticle used in the

majority of other scopes.

The Rheostat Dial is oriented at a 45 degree angle from the scope

centerline on ocular lens housing, to provide the shooter an unobstructed view
of the elevation turret markings. Control of the illumination is achieved by
simply rotating the Rheostat Dial in one direction or the other.

If you look closely at the side of the Dial you will notice a series of

numbers. “0” represents the Off position. If you turn the Dial in either
direction the reticle will illuminate blue or green (depending upon the direction
that it is turned). Each illumination color can be set to 5 levels of intensity, “1”

being the dimmest and “5” being the brightest. Adjust the brightness level as needed in accordance with
the surrounding conditions. The illumination will increase reticle visibility especially during dawn and
dusk. This illuminated scope is not intended for use in total darkness. When the illumination is turned off
the reticle will appear as normal Black Reticle. Be sure that the Rheostat Dial is set to the “0” position
when not in use to preserve battery life.


I. Battery Cap
J. CR2032 Battery


C.

Rheostat Knob