Dismounting, Dual color illuminated reticle, Battery installation – NcSTAR VCQBEP3540G User Manual
Page 5
5
Bore Sighting alone is not sufficient enough to ensure and accurate Zero. You must shoot you firearm
at the range in order to confirm a 100% accurate Zero. Follow these steps to fine tune your scope
adjustments:
1. Secure your firearm using a steady platform such as a rifle bench rest or sand bags.
2. Fire 3 to 5 carefully aimed shots at a target that is set to your desired Zeroing distance (100 yards is
recommended).
3. Observe where the bullet grouping have struck the target and make adjustments to the Elevation
and Windage settings as necessary until your point of aim matches your point of impact.
4. Continue with this process until you have achieved your desired level of accuracy.
5. Your scope is now Zeroed to your firearm at the distance that you have chosen.
It is important to remember that many factors can affect the accuracy of your scopes zero including
temperature, humidity, elevation, distance, angle, and other conditions. Changing ammunition brands can
affect accuracy as well.
Dismounting
To remove the CQB Scope from a rail, slide the Auto-Locking Latch located within the Quick
Release Lever away from the pivot point and swing the Quick Release Lever to the forward (Open)
position. You can then remove the CQB Scope from the rail.
Dual Color Illuminated Reticle
The CQB Series Scope models are equipped with a Blue and Green Illuminated Reticle feature, for
use when exterior lighting conditions are less than optimal. The Rheostat Dial for the Illuminated Reticle is
located on the left side of the scope body. Control of the Illumination is achieved by simply rotating the
Rheostat Dial in one direction or the other.
If you look closely at the Side of the Rheostat Dial you will notice a series of colored numbers. The
“0” represents the OFF positions. Each Blue and Green Illumination colors can be set to 3 levels of
intensity, “1” being the dimmest and “3” being the brightest. Adjust the brightness level as needed in
accordance with the surrounding conditions. The illumination will increase reticle visibility especially
during dawn and dusk. This illuminated scope is not intended for use in total darkness. When the
illumination is turned OFF the reticle will appear as a normal Black Reticle.
Be sure that the Rheostat Dial is set to the “0” position when not in use to preserve battery life.
Battery Installation
On the left side of the Turret Body you will find the Rheostat Dial. The Battery
housing is located within the Rheostat Dial, and can be accessed by twisting the thin
Battery Cap on top of the Rheostat Dial Counter-Clockwise ().