beautypg.com

Renkus-Heinz RHAON 32-Bit User Manual

Page 36

background image

Users Manual

36

Appendix III: RHAON Hardware Inputs, Outputs & Indicators, Dimensions

To connect a loudspeaker to the RHAON network, you first make the hardware connections, and then (if you are using CobraNet for digital

audio distribution) assign signal routing using RHAON software. Since all Ethernet connections are made using RJ45 connectors and

CAT5 cable, the network infrastructure is cost-effective and easy to install. You can also connect Serial Digital (AES3 aka AES/EBU) and

analog audio to an IC-R array, as well as Fault Detect and Fault Relay lines.

Primary & Secondary Ethernet

Inputs

RJ45 female:

when both inputs are connected, if

Primary fails changeover to Secondary

is automatic. Yellow LED flashes when

the connector is active, glows steadily

when data is streaming. Green LEDs

glow when connected but inactive, turn

Orange to indicate a faulty connection.

Overdrive LED

Flashes red when the Primary Analog

Input preamplifier is being over driven

Signal LED

Flickers when an audio signal of at

least -30 dBu is present at the primary

analog audio input.

Primary Analog Input/Output

XLR female

pin 1 chassis, pin 2 +, pin 3 -

Looping Secondary Analog Output

Phoenix connector, Pin 1 +, Pin 2 -,

Pin 3 chassis

Fault Detect

Opto-isolated input used to monitor the

presence of an external wiring loop;

absence of a voltage is reported to the

DSP and transmitted to the monitoring

computer over the Ethernet. Operates on

5 to 24 V DC. Pin 5 +, Pin 6 -

Fault Relay

NO / NC relay contacts used to report a

failure to an external monitoring system;

used mainly to trigger a failure indication

on a hard-wired monitoring device; handles

up to 0.5 Amps at 24 V AC or DC. Pin 4

normally open, Pin 5 swing blade, Pin 6

normally closed.

Secondary Analog Input

Phoenix connector; pin 1 +, pin 2 -,

pin 3 chassis

Mute Button

Turn loudspeaker muting on & Off

Push Button Volume Controls

Also function as a manual Standby/

On control

Input Pad & LED Indicator

On / Off 10 dB pad for Primary

Analog Input; allows input signals of

up to +24 dBu when inserted

Power LED

Glows when amplifier power is On

Thermal LED

Lights to indicate that an over-temperature

sensor has shut down the amplifier

Voltage Selector

Not on all models

90/260 V AC

IEC Power Connector

& AC Line Fuse

NOTE: To prevent inadvertent operation the Mute, Volume Up & Volume Down, Input Pad and AES/EBU push buttons need to be pressed

and held down for several seconds before they activate.

Looping Analog Output

XLR female

pin 1 chassis, pin 2 +, pin 3 -

AC Power ON/Off

Not under computer control by RHAON.

RHAON software can put the amplifier in Standby, but

a remote computer cannot disconnect the AC power.

To toggle between On and Standby manually, hold

both the Up & Down Volume push buttons down for

approximately 3 seconds.

This manual is related to the following products: