Renkus-Heinz RHAON 32-Bit User Manual
Page 26
Users Manual
26
SUPER
VISE
SUPERVISION
RHAON constantly checks (supervises) each loudspeaker in the system and provides system operators with a comprehensive set of moni-
toring and loudspeaker/amplifier management tools. It alerts the operator to a problem anywhere in the system and assists in identifying
the problem take corrective action.
The Status field at the bottom of each loudspeaker’s icon allows the operator to monitor all Loudspeakers or Groups at a glance. The
icon’s status bar continuously displays a text message that indicates the status of the loudspeaker. If RHAON detects a problem, the status
changes color and the text message defines the nature of the problem
If there is a problem with a loudspeaker in a Group, the Group icon will change color and display a text alert. If a Group icon displays an
alert (yellow or red bar with text), double-click it to Expand it and show all of its Loudspeaker icons. One of more of these icons will display
the same alert: double-clicking on it will open the loudspeaker’s Properties window in Supervise mode and provide additional information
on the nature of the problem.
A summary of the color/warning messages follows.
COLOR
MESSAGE
STATUS
GREEN
OK
This loudspeaker is (or all loudspeakers in this Group are) connected
and
operating
YELLOW
Overload
Amplifier is being over driven
RED
Unassigned
Virtual loudspeaker has not been assigned to a physical loudspeaker
RED
Offline
Loudspeaker has lost power or been disconnected from the network
RED
Driver Open
One of the loudspeaker’s drivers has failed
RED
Hot
An amplifier’s over temperature circuitry is engaged
RED
Limiting
An amplifier is being over driven or malfunctioning
RED
Amp Fail
An amplifier has failed
If a Group icon displays an alert (yellow or red bar with text), double-click it to Expand it and show all of its Loudspeaker icons. One of
more of these icons will display the same alert: double-click it to open the loudspeaker’s Properties window in Supervise mode.