beautypg.com

Maintenance, Cleaners, disinfectants and descalents, Storage – Stuart Turner Submersible Diver 35 & 45 Boostamatic User Manual

Page 7: Trouble shooting guide

background image

- 7 -

MAINTENANCE

WARNINGS:

Care should be taken to protect pump from frost and freezing.

Cleaners, disinfectants and descalents

On installations where chemical disinfectants or descalents are periodically

used, the compatibility of the chemical solution regarding the pump must be
considered.

Acid based descalents and aggressive cleaning agents must not come into

contact with the pump. The pump must be removed from the system prior to the
use of these products. The system should be flushed to remove all chemicals
before the pump is re-connected.

If in any doubt as to the suitability of the chemical solutions refer to Stuart

Turner Ltd.

STORAGE

If this product is not installed immediately on receipt, ensure that it is stored in a dry, frost

and vibration free location in its original packaging.

TROUBLE SHOOTING GUIDE

Symptoms

Probable Cause

Recommended Action

Pump will not start.
Control module failure
light illuminated.

Liquid supply low.

Check liquid level in the supply tank and all stopcocks are
open.
Reset the control module by depressing the restart button.

Inlet filter blocked
(if fitted).

Remove and clean filter gauze.
Reset control unit.

Electrical supply.

Check all electrical switches are on.
Is the correct fuse fitted?
Is the circuit breaker set?

Static inlet or outlet head
is greater than permitted.

Re-position control module.
(See siting of the pump and limits of application section).