beautypg.com

Stuart Turner Submersible Diver 35 & 45 Boostamatic User Manual

Page 17

background image

- 9 -

The wires in this mains lead (supply cord) are coloured in accordance with the following

code:

Green & Yellow: Earth

Blue:

Neutral

Brown: Live

As these colours may not correspond with the coloured markings identifying the

terminals in your plug, proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal in the

plug which is marked with the letter ‘E’ or by the earth symbol

or coloured green or

green and yellow.

The wire which is coloured blue must be connected to the terminal which is marked with

the letter ‘N’ or coloured black or blue.

The wire which is coloured brown must be connected to the terminal which is marked

with the letter ‘L’ or coloured brown or red.

Fuses

The following fuse size should be used with the appropriate pump.

Model

Fuse Size (AMPS)

All Models

13

Supply Cord Replacement

The power supply cord of this pump cannot be replaced. If the cord is damaged, the

pump should be scrapped.

Float Switch Cord Replacement

The float switch cord cannot be replaced. If the cord is damaged the pump should be

scrapped.

Supply Cord Extension (Pump)

The pumps are fitted with a supply cord suitable for outdoor and underwater use. The

cord specification is as follows:-

Pump Type

Cord Type

Cord Length (m)

Diver

HO7RN-F3 G 1.0 mm²

15

If an extension cord is necessary a cord of the proper type and rating must be used.
In general for 230 volt pumps on distances up to 40 metres (inclusive of original cord

length) the same specification cord as fitted to the pump can be used. For distances
above 40 metres a larger cord size may be required due to voltage drop and advice must
be obtained based upon installation details.

Any connectors or junction boxes must be specifically suited for outdoor use and

installed in accordance with manufacturers instructions.

Any cable routed underground must be protected to local standards.

Float Switch Cord Extension

The float switch cord cannot be extended.

Cont ...