Stuart Turner Submersible Diver 35 & 45 Boostamatic User Manual
Page 17

- 9 -
The wires in this mains lead (supply cord) are coloured in accordance with the following
code:
Green & Yellow: Earth
Blue:
Neutral
Brown: Live
As these colours may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal in the
plug which is marked with the letter ‘E’ or by the earth symbol
or coloured green or
green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with
the letter ‘N’ or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked
with the letter ‘L’ or coloured brown or red.
Fuses
The following fuse size should be used with the appropriate pump.
Model
Fuse Size (AMPS)
All Models
13
Supply Cord Replacement
The power supply cord of this pump cannot be replaced. If the cord is damaged, the
pump should be scrapped.
Float Switch Cord Replacement
The float switch cord cannot be replaced. If the cord is damaged the pump should be
scrapped.
Supply Cord Extension (Pump)
The pumps are fitted with a supply cord suitable for outdoor and underwater use. The
cord specification is as follows:-
Pump Type
Cord Type
Cord Length (m)
Diver
HO7RN-F3 G 1.0 mm²
15
If an extension cord is necessary a cord of the proper type and rating must be used.
In general for 230 volt pumps on distances up to 40 metres (inclusive of original cord
length) the same specification cord as fitted to the pump can be used. For distances
above 40 metres a larger cord size may be required due to voltage drop and advice must
be obtained based upon installation details.
Any connectors or junction boxes must be specifically suited for outdoor use and
installed in accordance with manufacturers instructions.
Any cable routed underground must be protected to local standards.
Float Switch Cord Extension
The float switch cord cannot be extended.
Cont ...