Fuses
The following fuse size should be used.
Intermediate Connecting Cord Replacement
The intermediate connecting cord (pump supply cord) which connects the pump to the
control module
cannot be replaced. If the cord is damaged the pump should be scrapped.
Cable Gland Fitting Instructions (Pressure Control Module)
See Pressure Control Module instruction book.
Intermediate Connecting Cord Extension (Boostamatic Diver 35 and 45)
The intermediate connecting cord which connects the pump to the control module is of a
type suitable for outdoor use. Cord specification is as follows:
H07RN-F3 G 1.0 mm² - 10 amp rating.
If an extension cord is necessary a cord of the proper type and rating must be used.
In general for 230 volt pumps on distances up to 40 metres (inclusive of original cord
length) the same specification cord as fitted to the pump can be used. For distances
above 40 metres a larger cord size may be required due to voltage drop and advice must
be obtained based upon installation details.
Any connectors or junction boxes must be specifically suited for outdoor use and
installed in accordance with manufacturers instructions.
Any cable routed underground must be protected to local standards.
NOISE
The equivalent continuous A-weighted sound pressure level at a distance of 1 metre
from the pumpset does not exceed 70 dB(A) for all models.
COMMISSIONING
WARNINGS:
The motor casing can become very hot under normal operating
conditions, care should be taken to ensure it cannot be touched during
operation.
Do not run pump without guards and terminal box lids correctly fitted.
Care should be taken to protect the pump from freezing.
The pump chamber must be full of liquid at all times. Seal damage will
result if the pump runs dry.
Ensure electrical supply is compatible with the details that are stated on the pump rating
plate. (The wrong voltage or frequency can be dangerous and may damage the pump.)
Priming
The pump should be fully submerged before starting, take care when submerging the
pump to ensure all air is purged from the casing. This is done by slowly submerging the
pump and gently agitating whilst doing so.
Model
Fuse Size (AMPS)
All Models
13