3 ELECTRICAL INSTALLATION / EARTHING

3.11

Regulations: The electrical installation must be carried out in

accordance with the current national electrical regulations and installed

by a qualified person.

3.12

Safety: In the interests of electrical safety a 30 mA residual current

device

(R.C.D. not supplied) must be installed in the supply circuit.

This may be part of a consumer unit or a separate unit.

3.13 Before starting work on the electrical installation ensure the power

supply is isolated.

3.14 The motor and wiring must not be exposed to water.
3.15 The supply cable must be positioned so that it is not stepped on,

cut or damaged.

3.16

Electrical Connection:

a) The pump is provided with a factory fitted supply cord.

b) This must be permanently connected to the fixed wiring of the mains supply.

c) Means for disconnection must be incorporated in the fixed wiring in

accordance with the wiring regulations.

d) A suitable method of connection would be via a double pole switched, fused

connection unit complying with BS 1363-4, protected with a fuse (see

technical specification section).

e) The connection unit should be mounted in an easily accessible position and

should be labelled if confusion is possible, to allow easy identification of the

flomate isolating switch.

3.17

Earthing: This appliance must be earthed via the supply cord, which must be

correctly connected to the earth point located in the terminal box.

3.18

Additional earthing: Certain installations may require additional earthing

arrangements such as equipotential bonding. Reference should be made to the

relevant regulations concerning this subject to ensure compliance.

3.19

Connections: The pump must be permanently connected to the fixed wiring of

the mains supply using the factory fitted supply cord, via a double pole switched

fused spur off the ring main and

NOT connected to the boiler or the immersion

heater

circuits.

3.20

Wiring Of Connection Unit:

WARNING: This appliance must be earthed.

The wires in the mains lead (supply cord) are coloured in accordance with the

following

code:

Green and Yellow:- Earth. Blue:- Neutral. Brown:- Live

As the colours of the wires in the mains lead of this appliance may not correspond

with the coloured markings identifying the terminals in your connection unit

proceed as follows:

a) Green and yellow wire must be connected to the terminal in the connection

unit which is marked with the letter ‘E’ or by the earth symbol

or coloured

green or green and yellow.