4 COMMISSIONING

4.11

Priming: This pump is self venting. Open the mains stopcock and allow the

pump to fill and vent, please note the pump chamber must be full of liquid at all

times. Seal damage will result if the pump runs dry.

4.12

Starting:

a) Ensure all outlets are closed, turn power supply ‘on’.

b) Open and close all outlets in turn associated with the pump allowing liquid to

flow from each outlet until all air is purged. As each outlet is opened and

closed the pump will start and stop respectively.

c) Any tap or control valve within the system when opened and closed will now

turn the pump on/off. Check system for leaks, if clear the system is now

operating

correctly

d) Carefully check pump and pipework for leaks whilst pump running and

stationary before leaving the installation unattended.

4.13

For Further Technical Support: Phone the Stuart Turner PumpAssist team on

0844 98 000 97. Our staff are trained to help and advise you over the phone.

Note: When pumps are installed in another manufacturers original equipment,

please contact the manufacturer for advice.

5 MAINTENANCE

5.11 Disconnect electrical supply before working on pump.
5.12 Turn off liquid supplies to the pump and release pressure by opening outlets

before attempting maintenance.

5.13 The flow restrictor inside the pump must be replaced every

2 years (contact

Stuart

Turner

Ltd).

5.14 If the installation is fitted with an inline suction strainer, the strainer must be

cleaned as necessary to ensure the pump has unrestricted flow.

5.15 No other routine maintenance is required.
5.16 After maintenance is completed, refer to Section 4 - Commissioning for