Stuart Turner Monsoon Extra 2.6 bar PS User Manual

Page 9

background image

- 9 -

Cont ...

4.19

Additional earthing: Certain installations may require additional earthing

arrangements such as equipotential bonding. Reference should be made to the

relevant regulations concerning this subject to ensure compliance.

4.20

Connections: The pump must be permanently connected to the fixed wiring of

the mains supply using the factory fitted supply cord, via a double pole switched

fused spur off the ring main and

NOT connected to the boiler or the immersion

heater

circuits.

4.21

Wiring of connection unit:

WARNING: This appliance must be earthed.

The wires in the mains lead are coloured in accordance with the following code:

Green and Yellow: Earth

Blue: Neutral

Brown: Live

As the colours of the wires in the mains lead of this appliance may not correspond

with the coloured markings identifying the terminals in your connection unit

proceed as follows:

The wire which is coloured green and yellow must be connected to the terminal

in the connection unit which is marked with the letter E or by the earth symbol:

or coloured green or green and yellow.

The wire which is coloured blue must be connected to the terminal which is

marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is

marked with the letter L or coloured red.

4.22

Wiring Diagram:

Model

Fuse Size (AMPS)

All Models

13

4.23

Fuses: The following fuse size should be used with the appropriate pump:

GREEN / YELLOW

BLUE

BROWN

L

M

A

N

N

L

E

N 230 VAC/1PH/50Hz

SUPPLY

RED

CAPACITOR

MOTOR

GREEN / YELLOW (LINK WIRE)

RE

D

YELLOW

RED

BLA

CK

BLACK

FLOWSWITCH
REED (S3)

S3 S3 S2

S2

S1

S1

PRESSURE
SWITCH (S1)

Monsoon Extra 2.6, 3.6 bar PS

Fig. 5