Stuart Turner Monsoon Extra 2.6 bar PS User Manual

Page 6

background image

- 6 -

Cont ...

2 LOCATION

2.26

The cold water supply: The supply must be AIR FREE and have a

DEDICATED CONNECTION to the tank which should be via a tank connector,

positioned at a slightly lower level (25 mm minimum) than the feed pipe to the hot

water

cylinder.

Do not connect to the mains.

2.27

Location: The pump must, for optimum performance, be sited as close as

possible to and never more than 4 metres from the HOT WATER cylinder. The

pump should always be sited BELOW the HOT WATER take-off from the cylinder.

Fig. 2

Cold
water

Hot water

Unvented hot
water cylinder

Static inlet pressure

Min. 1 m

Max. 10 m

Static outlet pressure

Max. 13 m