4 ELECTRICAL INSTALLATION / EARTHING
4.11
Regulations: The electrical installation must be carried out in
accordance with the current national electrical regulations and installed
by a qualified person.
4.12
Safety: In the interests of electrical safety a 30 mA residual current
device
(
R.C.D. not supplied) should be installed in the supply circuit.
This may be part of a consumer unit or a separate unit.
4.13 Before starting work on the electrical supply ensure power supply is
isolated.
4.14
DO NOT allow the supply cord to contact hot surfaces, including the
motor shell, pump body or pipework. The cord should be safely routed
and secured by cable clips.
4.15
Supplementary Bonding: The pressure set is factory fitted with a
supplementary earthing wire to ensure continuity throughout the assembly
(Fig. 3). It must be ensured throughout the product life that this electrical
connection remains in place.
4.17
Earthing: This appliance must be earthed via the supply cord, which must be
correctly connected to the earth point located in the terminal box.
4.18
Pipework: Copper or metallic pipework must have supplementary earth bonding
where the continuity has been broken by flexible hoses or plastic components.
4.16
Adjacent pipes: Adjacent suction and delivery pipes should be fitted with
earthing clamps to BS 951 in accordance with current regulations (Fig. 4).