Stuart Turner Monsoon Extra S1.4 bar Single User Manual
Page 10
![background image](/manuals/360709/10/background.png)
- 10 -
4.21
Wiring Diagrams:
Model
Fuse Size (AMPS)
Monsoon Extra S1.4 bar
5
4.22
Fuses: The following fuse size should be used with the appropriate pump:
4.23
Supply Cord Replacement:
The supply cord and internal wiring within the terminal box are
routed and secured to ensure compliance with the electrical
standard EN 60335-1. It is essential that prior to any disturbance
of this internal wiring, all cable routing and securing details are
carefully noted to ensure re-assembly to the same factory pattern
is always maintained.
If the supply cord is to be changed or is damaged, it must be replaced with a
special cord assembly available from Stuart Turner or one of their approved
repairers.
On disassembly note the cord retention and routing system. Re-assemble to the
same
pattern.
For information on cable connection consult the wiring diagram and cable gland
fitting
instructions.
4.24
Cable Gland Fitting Instructions:
To enable correct assembly of the cable gland the
‘O’-ring (Fig. 9 item 1) must be placed over the cable
before the clamping insert (Fig. 9 item 2) can be
tightened.
Note: Cable diameter range:- 6.5 mm to 9.5 mm.
4.25
Supply Cord Extension:
The pumps are fitted with a supply cord to the following
specification:-
All models . . . . . . . . . . . . . . . . . HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be
used. Any connections or junction boxes used should be specifically suited for
the application and installed in accordance with the manufacturers instructions.
Fig. 9
2
1
MAIN WINDING
THERMOTRIP
CAPACITOR
START WINDING
LIN
K WIRE (BLUE)
BROWN
BLA
CK
GREEN/
YELLOW
BLUE
BROWN
L
M
A
N
N
S2 S3 S3 S2
L
E
N
FLOWSWITCH
REED (S3)
S1
S1
BLUE
Monsoon Extra S1.4 bar Single
Fig. 8