The cold water supply: The supply must be air free and have a dedicated

connection to the tank which should be via a tank connector, positioned at a

slightly lower level (25 mm minimum) than the feed pipe to the hot water cylinder.

Do not connect to the mains.

2.28

Location: The pump must, for optimum performance, be sited as close as

possible to and never more than 4 metres from the HOT WATER cylinder. The

pump should always be sited BELOW the HOT WATER take-off from the cylinder.

2 LOCATION - HOT WATER

2 LOCATION - COLD WATER

Table 1

Model

Min.

static

inlet

head

(m)

Max.

static

inlet

head

(m)

Max.

static

outlet

head

(m)

U2.0 bar Single

0.5

8

8

U3.0 bar Single

0.5

12

12

U4.5 bar Single

Fig. 4

Static Inlet Pressure

(see table 1)

Static Outlet Pressure (see table 1)

Fig. 5

Static Inlet Pressure

(see table 1)

Static Outlet Pressure (see table 1)