Data accumulator - types of data – MAHLE RTI Laser 4 User Manual
Page 9

Page 9
DATA ACCUMULATOR - TYPES OF DATA
CATEGORY...
Three categories of data can be entered into the Data Accumulator during a typical alignment
procedure. Some data is entered manually, determined by measurements observed or from a
specification book. Other data is entered through the Readout from the Electronic Gauge during the
actual alignment process. The three types of data are spec, before, and after. The type of data to be
entered is selected by pressing the appropriate BEFORE, SPEC, or AFTER key (Item 3, Page 7).
BEFORE
This data is entered during the initial check of the vehicle.
SPEC
This data is entered from an Alignment Specification Manual.
AFTER
This data is entered after alignment adjustments are complete.
PARAMETER...
Four parameters are evaluated during a typical alignment; Camber, Caster, SAI, and Toe. Data for
each of these parameters is entered by pressing the appropriate CAMBER, CASTER, SAI, or TOE
key (Item 5, Page 7). This data is recorded for each of the three categories mentioned above; Before,
Spec, and After.
CAMBER
This data is read by the Data Accumulator directly for Before and After.
The Spec data is entered manually.
CASTER
This data is read by the Data Accumulator directly for Before and After.
The Spec data is entered manually.
SAI
This data is read by the Data Accumulator directly for Before and After.
The Spec data is entered manually.
TOE
This data must be entered manually for Before and After as observed on the
laser beam instrumentation as described in the Toe Reading section. The
Spec data is entered manually.
WHEEL DESIGNATION...
Data is entered for each of the four wheels on the vehicle. The parameters mentioned above are entered
for the wheel selected by pressing the appropriate key (Item 6, Page 7)