MAHLE RTI CSC10 User Manual
Page 12

- 11 -
START THE RECYCLING PROCESS:
1. Plug the electric cord into a 115 volt, 60 Hz, grounded receptacle.
Use a 16 gauge (minimum) grounded extension cord if necessary.
2. Open the Valve on the CSC10R YELLOW Hose and insert the hose
into the small opening of the Clean Coolant Drum (extra 15 gallon
drum supplied with the unit).
3. Press the Process Switch to the ON position at the Recycling Center
(rear of unit) to start the Recycling Pump.
4. When the CSC10R Waste Coolant Drum is empty, push the Process
Switch to the OFF position.
5. Remove the YELLOW Hose from the Clean Coolant Drum. Close the
Valve and return the hose to its Hose Clip on the side of the CSC10R.
NOTE: If the filtering process takes more than 10 minutes or stops completely, the filters require
changing. refer to the "Maintenance Schedule" section of this manual for complete instructions.
|
|
|
|
CAUTION:
Never allow the Filter Pump to operate without liquid. running the pump dry will cause
premature wear or damage to the pump and is not covered under warranty.
The filtered coolant is now ready for reinhibiting. Add RTI's Automotive Reinhibitor For CSC10R
according to the bottle's label or the "Adding The Inhibitor" section of this manual.
ADDING THE REINHIBITOR
Once the coolant has been processed through the Recycling Center, the final step is to reinhibit the
coolant to adjust the pH and replenish depleted corrosion inhibitors, buffers, anti-foaming agents and
dyes.
|
|
|
|
WARNING:
The reinhibitor package is poisonous and corrosive. Before using the RTI Automotive
Reinhibitor for CSC10R, read all warnings and precautions on the bottle's label.
1. Using the supplied Hand Pump, pump a small amount of the processed coolant into the Measuring
Cup and measure the freeze point using the Coolant Tester or a Refractometer.
2. Adjust the freeze point to obtain the desired freeze/boil protection. Most engine manufacturers
recommend a freeze protection around -34
0
F. If the freeze point is between -40
0
F and -60
0
F, add
water to raise the freeze point. Use distilled or demineralized water to prevent scale and mineral
build-up. If the freeze point is between -30
0
F and -4
0
F, add straight antifreeze to lower the freeze
point.