MAHLE RTI TechAlert User Manual
Page 10

9
SYNCHRONIZATION (Continued)
Checking the Remote for Synchronization with Base Modules
Press and hold the Remote Push Button until all four LED’s light and 
release the push button. The status of all 4 LED’s are shown at the 
same time to indicate which LED has an assigned status based on the 
following: 
 
• Solid Red LED – no assignment
• Solid Green LED – channel is assigned and currently active
Desynchronizing a Remote from a Base Module
Press and hold the Remote Push Button for (3) consecutive flashes of all 
4 LED’s and then release the push button. The status of channel 
assignment is based on the following: 
 
• Solid Green LED – Channel is assigned
• Solid Orange LED – Channel is assigned, but monitoring is
ignored
• Solid Red LED – Channel is not assigned
 
When entering Desynchronization mode, the #1 channel indicates its 
status first. To advance to the next channel, press the push button for 
one second and then release. Continue with this process to advance to 
the desired channel. To change channel status (starting from a channel 
that is assigned showing a green LED), press and hold the Remote Push 
Button for (3) seconds and release. The status LED will change to 
Orange to indicate that the channel is still assigned, but channel 
monitoring is being ignored. Press and hold the Remote Push Button for 
(3) seconds and release again. The status LED will change to Red to 
indicate that the channel is desynchronized. When the desired status is 
attained, allow the desynchronization mode to time out to accept the 
change. 
 
Desynchronization mode will time out after 20 seconds and the remote 
will return to normal operation. 
 
BASE MODULE OPERATION
Base LED Descriptions
There are several different LED’s shown on the Base Module to indicate 
different signals being sent to the Remote Module. 
 
 
 