Fresh air heater, Fresh-air - features and specifications, Fresh-air application 1-2 – Thermolec Application &Technical Notes User Manual
Page 60: Application # 1, Fresh air heater application # 2

Application # 1
Thermo-Air complementing a heat
recovery ventilation system.
At low temperature, a heat recovery ventilation
system cannot recover enough heat to pre-heat the
incoming outside air to a comfortable level.
A THERMO-AIR heater is the ideal solution to restore
efficiency to the system. It is equipped with an
electronic controller that proportionally modulates the
heating load to match the exact capacity required,
thus minimizing operating cost. It’s super-sensitive
air flow sensor, monitors the quantity of air flowing
through the heater, adjusts the heater’s capacity to
match the air flow available and shuts the heater
down in case of a total loss of air.
FRESH AIR HEATER
FRESH AIR HEATER
Application # 2
Thermo-Air complementing a
central forced-air heating
system.
With an existing central forced-air heating system,
the furnace fan can be used to bring new outside air
into the system. Preheating that air at the source
will improve the performance of the furnace and the
life expectancy of the heat exchanger.
The THERMO-AIR heater is equipped with a
modulating controller which uses the minimum
amount of energy, thus avoiding waste, and a
super-sensitive air flow sensor which permits the
heater to operate only when the fan is running.