Commands – Watlow Series 734 Data Communications User Manual
Page 19
How to Use Data Communications
19
WATLOW Series 733/734
Name
Description
Read (?) and/or Write (=) Syntax
Range
(data.1)
Add ETX & STX with ANSI X3.28 Protocol
(data.2)
MDKY Mode Key Action
=
1 = One MODE Key press
MDL
Model Number
?
x1 = 3 or 4; horiz. or vert. unit
Responds 73x-xx-x
x2 & x3 = Last two
(See Model # , p. 21)
characters of model #, AA-XX
x4 = Software rev; 0-9 or A-X
MENU Menu Step
?
Data entered must be within
individual prompt guidelines,
=
i.e., SP1 = R1L to R1H, etc.
step
Enter data for sp2 and events
hours or minutes
even if they are not available.
seconds
See 733/4 Program Manual.
MODE Mode Status
?
0 = Operation mode
1 = Program mode
2 = Setup mode
3 = Service mode
4 = Calibration mode
MS
Melt Cycle
?
0 = Melt cycle OFF
=
1 = Melt cycle ON
PB1
Zone 1 Prop Band
?
0 to 999°F
=
0 to 555°C
PB2
Zone 2 Prop Band
?
0 to 999°F
=
0 to 555°C
0 to 999 Units
RA1
Zone 1 Rate
?
0 to 9.99 minutes
=
RA2
Zone 2 Rate
?
0 to 9.99 minutes
=
RE1
Zone 1 Reset
?
0 to 9.99 repeats per minute
=
RE2
Zone 2 Reset
?
0 to 9.99 repeats per minute
=
RH1
Zone 1 Range High
?
RL1 to max. INP1 type range
=
RH2
Zone 2 Range High
?
RL2 to max. INP2 type range
=
RL1
Zone 1 Range Low
?
Min. INP1 type range to RH1
=
RL2
Zone 2 Range Low
?
Min. INP2 type range to RH2
=
RTD
RTD Curve
?
0 = DIN
=
1 = JIS
RUN
Menu Run
=
n = Run Menu n
SIL
Alarm Silence
?
0 = OFF
=
1 = ON
STAT
Run Status
?
x x; x1=0 idle or 1 run, x2=menu#
STP
Maximum Steps
?
1 = 1 Step
=
2 = 2 Steps
3 = 3 Steps
STOP
Menu Stop
=
n = Stop Menu n
TCMP Temperature
?
0 = OFF
Compensation
=
1 = ON
TREM Time Remaining
?
Learn Menu time remaining
TS
Time Select
?
0 = minutes : seconds
=
1 = hours : minutes
Table 5 -
Command Summary
with Read (?) and
Write (=) Simple
Syntax and Data
Range/Responses.
Commands