13

WATLOW Series 733/734

How to Use Data Communications

XON/XOFF "?"

Figure 7 -
XON/XOFF "?"
Command Example.

0

0

30

5

35

30

CR

0D

ASCII
Characters

HEX
Value

13

11

XON/XOFF "?" Command Example

You want to know the Alarm 1 Low (A1LO) value. The "?" uses a variation of the
message syntax shown just below. This protocol requires an ending carriage
return character.

"?" Command syntax with XON/XOFF Protocol:
? data.1

Enter in ASCII:
? A1LO
The hex string will be:
3F2041314C4F0D

The value of A1LO will be between rL (Range Low) and rH (Range High), say, 500.

Response from the Series 733/734:

The hex response string is:
13113530300D

ASCII
Characters

HEX
Value

1

4 1

4C

3 1

Space

?

3F 2 0

A

L

ace

CR

0 0D

4F

O