PS-3710A/PS-3711A Series Hardware Manual

2-34

RAS Interface

The PS-A unit side connector is a D-Sub 25 pin plug type.

Interfit Bracket

#4-40 (UNC)

Pin Arrangement

Pin No.

Signal Name

Meaning

1

GND

Ground

2

+5V

Output Current:100mA or less

(with a total of 2 pin and 15 pin)
Output Voltage:5V±5%

3

+12V

Output Current:100mA or less

Output Voltage:12V±5%

4

NC

-

5

RST(+)

Reset in (+)

6

DIN0(+)

Data in 0 (+)

7

DOUT2(-)
(UPS Shutdown(-))

Data out 2 (-)

(UPS Shutdown (-))

8

DOUT2(+)
(UPS Shutdown(+))

Data out2(+)

(UPS Shutdown (+))

9

DOUT0(-)

Data out 0 (-)

10

DOUT0(+)

Data out 0 (+)

11

RST(-)

Reset in (-)

12

DIN0(-)

Data in 0 (-)

13

DIN1(+)

Data in 1 (+)

14

GND

Ground

15

+5V

Output Current:100mA or less

(with a total of 2 pin and 15 pin)
Output Voltage:5V±5%

16

DIN2(+)

Data in2(+)

17

DIN2(-)

Data in2(-)

18

DIN3(+)

Data in3(+)

19

DOUT1(-)

Data out1(-)

20

DOUT1(+)

Data out1(+)

21

DOUT3(-)

Data out3(-)

22

DOUT3(+)

Data out3(+)

23

DIN3(-)

Data in3(-)

24

DIN1(-)

Data in1(-)

25

NC

• Be sure to use only the rated voltage level when using the No. 2, 15 [+5V] and

No.3 [+12V] for external power output. Failure to do so can lead to a unit

malfunction or accident.