beautypg.com

Proface APL3000B - Node Box PC User Manual

Page 102

background image

Chapter 4 Maintenance

4-5

• The gasket must be inserted correctly into the groove for the PS-A’s moisture

resistance to be equivalent to IP65f.

• Since the gasket is flexible but not elastic, be careful not to stretch it

unnecessarily, as doing so could tear the gasket.

• Be sure the gasket’s seam is not inserted into any of the unit’s corners, only in the

straight sections of the groove. Inserting it into a corner may lead to its eventually

tearing.

• To ensure stable resistance against dust and moisture, insert the gasket so that

the seam is at the bottom of the PS-A unit.

• The upper surface of the gasket should protrude approximately 2.0mm [0.08in.]

out from the groove. Be sure to check that the gasket is correctly inserted before

installing the PS-A into a panel.

2.0mm[0.08in.]

Unit: mm[in.]