background image

17

unit without adjusting the Panel Cut size.
As shown in the following diagram, simply
remove 7 screws from the upper and lower
positions to remove attachments from the
PL-3600K series unit.

Panel Cut size without attachment

(2) Confirm that the installation gasket is

attached to the PL unit and then place the
PL unit into the panel from the front.

• It is strongly recommended that you

use the installation gasket, since it
absorbs vibration in addition to repel-
ling water.
For the procedure for attaching the
installation gasket, refer to “PL3000
Series Hardware Manual”.

(3) Insert each fastener’s hook into the slot

and tighten it with a screwdriver. Tighten
the screws gradually in an even, criss-
cross pattern.
The number of the slots varies depending
on the model.
PL-3600T Series : 4 slots
PL-3600K/3700T Series: 8 slots
PL-3700K/3900T Series: 12 slots

PL

X

Y

Panel

thickness

PL-3600K Series
(3612KPM/
4612KPM
compatible)

383.54
[15.10]

275.59
[10.85]

1.6[0.06]
to
10.0[0.39]

Attachments

Insertion Slots

Locations of the 4 slots

Insertion

Slots

Locations of the 8 slots

Insertion

Slots

Locations of the 12 slots