15 installation – Proface APL3000B - Node Box PC User Manual
Page 15
![background image](/manuals/358969/15/background.png)
15
Installation
• Determine the thickness of the board in
consideration of its strength. The mini-
mum thickness of a board is 1.6 mm
[0.06 in.] for M4 screws.
• M4 screws are not included with the PL
unit. Please prepare them by yourself.
(1) Create holes and perform the necessary
processing on the board according to the
drawing of mounting holes.
(2) Attach installation fasteners with the
accompanying four screws (M3) to the
PL unit. Pay close attention to the
direction of the fasteners. The torque
required to tighten these screws is 0.5 to
0.6N•m.
(3) Attach the PL unit to the board with the
screws (M4): First, tighten the screws
temporarily on the board; mount
installation fasteners temporarily onto
the screws; and then tighten the screws
until the PL unit is securely fixed.
The torque should be 1.0 to 1.2N•m.
Horizontal mounting
243 [9.57]
4-M4 [0.16]
258±0.3 [10.16±0.01]
270 [10.63]
35.5
[1.
4
]
220±0.
3
[8.
66±0.0
1
]
277 [
10.91]
Vertical mounting (4 slot type)
177 [6.97]
4-M4 [0.16]
192±0.3
[7.56±0.01]
204 [8.03]
35.
5
[1
.4
]
2
20±
0
.3 [8.
66±0.
01]
277
[
10.91
]
Wall mounting
35.5
[1.4]
4-M4
[0.16]
220±0.3
[8.66±0.01]
277 [10.91]
2
43 [
9
.5
7]
258
±
0.
3 [10.
16±0.01
]
270 [10
.63]
Horizontal mounting
or wall mounting
Vertical mounting
Screws
Screws
Enlarged view
Ex.: Horizontal mounting