• When using the display unit with a cable other than FP-DV01-100 (such as FP-
DVD01-50), use the Factory Setting.
• The default Resolution and Screen Refresh Rates are as follows.
Resolution : SVGA (800x600)Screen
Refresh Rate: 60Hz
Maximum resolution varies depending on the FP3000 Series models. Please customize it for
your FP model.
2.
Internal switches of the front module
Touch Panel Set Switch
Switch
Location
Switch Name
Factory
Settings
Description
SW1
Touch Panel
Set Switch
1:ON, 2:ON,
3:OFF, 4:OFF
4-point DIP switch. For Touch Panel Set Switch
details, see “
SW2
—
Version
Dependant
Internal setting.
Do not change. (Factory setting)
PL-3600* Series : 1, 2, 3: ON, 4: OFF
PL-3700* Series : 1, 3: ON, 2, 4:OFF
PL-3900T Series : 1, 2, 4: OFF, 3:ON
Switch
No.
Description
ON
OFF
Factory
Settings
Notes
1 to 2
Internal setting
Reserved Reserved
ON
Do not change. (Factory setting)
3
OFF
4
Cancellation function
of two point touch on
the touch panel
*1
*1
When two points are pushed, it is considered that middle point between the two points is touched
according to the nature of the analog resistive touch panel. When the switch, etc. is set on the
middle point, it will be enabled and may operate. To prevent such a switch from malfunction in
case of pushing two points, turn ON Switch No.4 in advance, then the middle point will be disabled
for two point touch.
Enabled Disabled OFF
The middle point is not considered
to be touched when the switch is
ON.
It is considered to be touched when
the switch is OFF.
SW1
SW2
ON
ON
Rear face of the front module