beautypg.com

Specifications, model numbers, 5/2-way double valves with c, Sensing – Ross Controls CATEGORY 4 - 5_2 VALVES CROSSMIRROR SERIES 77 User Manual

Page 3: Ross, Irror

background image

3

www.rosseuropa.com

Design

: Metal-to-metal spool-and-

sleeve valves, pressure-operated.
Air and spring returned.

Operation:

Solenoid-operated air-

piloted valves, 3/2-way-spring-return.

Media

2)

:

compressed air,

dehydrated, filtered (5 µm),
lubricated or unlubricated.

Operating pressure:

2,5 to 10 bar.

Temperature range:

4° C to 50° C.

Mounting orientation:

preferably

vertically.

Monitoring

1)

:

dynamically, cyclically,

internally.

Pilot solenoid:

according to VDE 0580.

Enclosure rating acc. to DIN 400 50 IP
65. Connector socket according to DIN
43650 Form A.

Solenoids

rated for continuous duty.

Standard voltages:

24 V DC 110 V DC
24 V 50 Hz, 110 V 50 Hz, 230 V 50 Hz;
24 V 60 Hz, 110 V 60 Hz, 240 V 60 Hz.

Power consumption:

DC solenoids - 5,3 W
AC solenoids - 8,5 VA

SPECIFICATIONS

Notes

1) In addition, a pressure-switch-monitored model of this valve is available. In case of a malfunction or pressure failure, the pressure
switch can be used for signaling abnormal operation.

Important Note:

The pressure switch is not designed to be integrated in a safety

circuitry as its response may be delayed, depending on the type of malfunction.

2) It is recommended to use compressed air, filtered and unlubricated. If lubricated air must be used, we recommend oils conforming to
ISO viscosity classes 32-46 (DIN 51519).

3) When ordering the valve, specify AC or DC voltage and frequency for operating the pilot solenoids (see Specifications above).

5/2-Way Double Valves

with C

ROSS

M

IRROR

®

-Sensing

The double valves listed have been approved by the following testing
and certificating authority:

BG-Fachausschüsse Eisen und Metall III und Hebezeuge II,
Deutschland: Certificate No. 99035

Double Valve

Nominal

Pipe size

Weight

Design

Model Number

Diameter

1

2

3

4

5

(kg)

Feature

10

G 1/2

G 3/8

G 3/8

G 3/8

G 3/8

1,1

D996C91

10

1/2 NPT 3/8 NPT 3/8 NPT 3/8 NPT 3/8 NPT

1,1

996C91

15

G 3/4

G 1/2

G 1/2

G 1/2

G 1/2

1,6

D1049C91

15

3/4 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT

1,6

1049C91

15

G 3/4

G 3/4

G 3/4

G 3/4

G 3/4

1,6

D1153C91

15

3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT 3/4 NPT

1,6

1153C91

Sub-base is equipped

with check valve in

pipe connection 1 and
2/2-way valve as reset

after pressure energy

failure

Sub-base

Nominal

Size Operating pressure

(bar)

Weight

Type

Model Number

3)

Replacement valve

3)

Diameter

min.

max.

(kg)

(with sub-base)

(without sub-base)

10

G 3/8

2,5

10

3,8

CM 5/2

D7776A3410

7776A3400

10

G 3/8

2,5

10

3,9

CM 5/2

D7776A3411

7776A3401

with pressure switch

15

G 1/2

2,5

10

4,8

CM 5/2

D7776A4420

7776A4400

15

G 1/2

2,5

10

5,1

CM 5/2

D7776A4421

7776A4401

with pressure switch

15

G 3/4

2,5

10

4,8

CM 5/2

D7776A5410

7776A4400

15

G 3/4

2,5

10

5,1

CM 5/2

D7776A5411

7776A4401

with pressure switch