PRODUCT DATA SHEET INFORMATION

5/2 CROSSMIRROR

®

Series 77

This valve is not designed for use in power press clutch/brake applications.

Designing to save
energy and reduce
greenhouse gases.

environment

safety

Designing toward
Zero-Harm.

Designing to optimize
reduction processes
and applications.

technology

Designing to
maximize return
on investment.

productivity

EMIII HZ

99035

BG

-PR

UFZER

T

ISO 13849-1:2006 Category 4

PL e applications

Cylinder Return to

Home Position

Solenoid Pilot Controlled Pneumatic Double Valve

Control Reliable Energy Isolation

Self-contained dynamic monitoring system requires no additional valve
monitoring controls

Base mounted, stainless steel spool valve construction

Status indication switch (ready-to-run) to inform machine controller of valve
condition; MUST be integrated into machine controls in order to prevent run
signal until fault is cleared in valve

Applications include small size pneumatic cylinder-operated presses, valve
operators, and safety latches

Base mounted, stainless steel spool valve construction

Sistema library data available (consult ROSS or visit the Safety industry page at
www.rosscontrols.com)

Explosion proof solenoid pilot available, for more information consult ROSS

Pilot Solenoids: Rated for continuous duty.
Standard Voltages: 100-110 volts, 50 Hz; 100-120 volts, 60 Hz;
24 volts DC; 110 volts DC. For other voltages, consult ROSS.
Power Consumption: Each solenoid, 18 VA inrush, 14 VA
holding on 50 or 60 Hz; 6 watts on DC.
Electrical Connections: Uses cord-grip connectors at solenoids.
Order connectors separately, see accessories.
Ambient Temperature: 40° to 120°F (4° to 50°C).
Flow Media: Filtered air; 5 micron recommended.
Inlet Pressure: 40 to 150 psig (2.5 to 10 bar).
Media Temperature: 40° to 175°F (4° to 80°C).

A

B

C

Ordering Information

Standard Specifications

Valve Size 2

Model*

Port Sizes

C

V

Pressure

Dimensions

inches (mm) Weight Replacements*

Number

1 2, 3, 4, 5 1-2 1-4 2-3 4-5

Switch

A

B

C lb (kg)

Valve No.

Base No.

7776A3410 1/2 3/8 2.0

1.6

1.6

2.8

Without

11.1 (282) 4.1 (104) 3.2 (81)

7.6 (3.4)

7776A3400

996C91

7776A3411 1/2 3/8 2.0

1.6

1.6

2.8

With•

11.1 (282) 6.7 (170) 3.2 (81)

8.4 (3.8) 7776A3401

996C91

* Model number includes base supplied with NPT threads. For BSPP threads, order model or base with a “D” prefix, e.g., D7776A3410, D996C91.
• For pressure switch option, order model or valve with a “Z” suffix for 110 volts AC or “W” suffix for 24 volts DC, e.g., 7786A3411Z, 7776A3401Z.

Valve Size 4

7776A4420

3/4

1/2

3.2

3.4 2.7

7.2

Without

12.1 (307) 4.3 (109) 4.1 (104) 10.2 (4.6) 7776A4400

1049C91

7776A4421

3/4 1/2

3.2 3.4 2.7 7.2

With•

12.1 (307) 6.9 (175) 4.1 (104) 11.2 (5.1)

7776A4401

1049C91

7776A5410

3/4 3/4

3.2 3.4 2.7 7.2

Without

12.1 (307) 4.3 (109) 4.1 (104) 10.2 (4.6)

7776A4400 1153C91

7776A5411

3/4 3/4

3.2 3.4 2.7 7.2

With•

12.1 (307) 6.9 (175) 4.1 (104) 11.2 (5.1)

7776A4401 1153C91

* Model number includes base supplied with NPT threads. For G threads, order model or base with a “D” prefix, e.g., D7776A4420, D1049C91.
• For pressure switch option, order model or valve with a “Z” suffix for 110 volts AC or “W” suffix for 24 volts DC, e.g., 7776A4421W, 7776A4401W.

Valve Size 4 SAE

S7776A4H10

SAE 12

SAE 12

3.2 3.4 2.7 7.2

Without

12.1 (307) 4.3 (109)

4.1 (104) 10.2 (4.6)

7776A4400 1159G91

S7776A4H11

SAE 12

SAE 12

3.2 3.4 2.7 7.2

With•

12.1 (307) 6.9 (175)

4.1 (104) 11.2 (5.1) 7776A4401 1159G91

* Model number includes base. • For pressure switch option, order model or valve with a “Z” suffix for 110 volts AC or “W” suffix for 24 volts DC, e.g.,
S7776A4H11Z, 7776A4401Z.

Pressure

Switch

Chambers

Base

Air Supply

Pilot

Valve

3

1

5

4

2

Base

Pilot

Valve