Ramsey Winch RE 34,9 User Manual
Ramsey winch company, Model re 34,9 owner’s manual electric winch
Ramsey Winch Company
Model RE 34,9 Owner’s Manual
Electric Winch
English (Original Instructions) .. . . . . . . . . . . . . . . . . . . 1
Français (Traduction des instructions originales) . . . . . .13
Deutsch (Übersetzung der Originalanleitung) . . . . . . . . .23
Español (Traducción de las instrucciones originales) . . .33
CONTENTS
User’s Responsibility for CE Compliance . . . . . . .2
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . .2
Tips For Safe Operation . . . . . . . . . . . . . . . . . . . .2
Techniques of Operation . . . . . . . . . . . . . . . . . . .3
Rope Installation . . . . . . . . . . . . . . . . . . . . . . . . .2
Winch Installation . . . . . . . . . . . . . . . . . . . . . . . .4
Electrical connections and Operations . . . . . . . . .4
Operating Instructions . . . . . . . . . . . . . . . . . . . . .4
Rated Load Limiter Adjustment . . . . . . . . . . . . . .4
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
End of Service Measures . . . . . . . . . . . . . . . . . . .5
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . .5
Winch Parts List . . . . . . . . . . . . . . . . . . . . . . . 6-7
Solenoid Parts List/Fairleads & Switch . . . . . . . . .8
Test Procedure for Solenoid . . . . . . . . . . . . . . . .9
Test Procedure for Motor . . . . . . . . . . . . . . . . . .10
CE Declaration of Conformity . . . . . . . . . . . . . . .12
WARNINGS:
THE USER SHALL ENSURE THAT THE OPERATING
PERSONNEL ARE GIVEN THE NECESSARY TRAINING.
THE OPERATOR SHALL ALWAYS WORK IN COMPLIANCE
WITH THE OPERATING INSTRUCTIONS.
CLUTCH MUST BE FULLY ENGAGED BEFORE STARTING
THE WINCH.
DO NOT DISENGAGE CLUTCH UNDER LOAD.
STAY OUT FROM UNDER AND AWAY FROM RAISED
LOADS.
STAND CLEAR OF ROPE WHILE PULLING. DO NOT TRY
TO GUIDE ROPE.
DO NOT USE WINCH TO LIFT, SUPPORT, OR OTHERWISE
TRANSPORT PERSONNEL.
A MINIMUM OF 2 WRAPS OF ROPE AROUND THE DRUM
BARREL IS NECESSARY TO HOLD THE LOAD.
AVOID CONDITIONS WHERE LOAD SHIFTS OR JERKS
OCCUR. EXCESSIVE “INCHING” SHALL BE AVOIDED.
Intended Purpose: Vehicle recovery and pulling of loads
914218-1012-
C
RAMSEY WINCH COMPANY
Post Office Box 581510 Tulsa, Oklahoma 74158-1510 USA
Phone: (918) 438-2760 Fax: (918) 438-6688
Visit us at http://ww.ramsey.com
Ramsey Authorized Representative in the Community:
(Please contact for regulatory inquiries only.)
Alura Group BV
P.O. Box 18626
2502 EP The Hague
The Netherlands
Tel: (31) (0) 70 362-4896
Fax: (31) (0) 70 346-7299
Ambient Temp Range
-28C to 60C (-20F to 140F)
Noise Level
80db
LAYER OF ROPE
1
2
3
Rated Line Pull Per Layer
kN
34,9
28,9
24,9
lb
7,840
6,500
5,600
Cummulative Rope Capacity
Per Layer
m
4
12
21
ft
15
40
70
Line Pull First Layer
kN
No
Load
8,8
17,7
26,6
34,9
lb
2,000
4,000
6,000
7,840
* Line Speed First
Layer 12 Volt
MPM
6,1
2,9
2,1
1,6
1,3
FPM
20
9.5
7
5.3
4.3
* Line Speed First
Layer 24 Volt
MPM
4,5
2,2
1,6
1,2
0,9
FPM
15
7.5
5.5
4
3
Amp Draw
12V
90
170
235
305
370
24V
36
75
105
140
170
* These specifications are based on recommended 10 mm (.393”) 1960 grade wire rope.
Document Outline
- 914218-1012 B EN RE34,9
- 914218 1012 B FR RE34,9
- 914218 1012 B DE RE34,9
- 914218 1012 B ES RE34,9