beautypg.com

Typical layout, Hydraulic system requirements – Ramsey Winch Powermaster Series 20K Bumper and Winch User Manual

Page 5

background image

3 OM-914206-1208-B

CONTROL VALVE

3 POSITION

4 WAY VALVE

(MOTOR SPOOL)

HIGH PRESSURE LINE

DUAL-A & B PORT CONTROL

WITH BRAKE RELEASE SHUTTLE

BRAKE

PORT

B

MOTOR

A

TYPICAL LAYOUT

LOW PRESSURE LINE

PUMP

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts, below, to properly match your hydraulic system to the Powermaster 20K
winch performance. The charts consist of:

(1) Line pull (lb.) first layer vs. working pressure (PSI) and (2) Line speed, first layer (FPM) vs. gallons per

minute (GPM). Performance based on a motor displacement of 14.9 cubic inches with 30 GPM maximum
flow rate. Motor has (2) 1.062-12 SAE straight thread o-ring ports.

Note:

A motor spool (open center) directional control valve is required for brake operation.

PERFORMANCE CHARTS


BASED ON 14.9 CU IN/REV MOTOR


0

5000

10000

15000

20000

0

500

1000

1500

2000

2500

WORKING PRESSURE, PSI

LI

N

P

U

LL,

 LBS

FIR

ST

 LA

Y

ER

0

5

10

15

20

25

30

35

40

45

0

5

10

15

20

25

30

FLOW, GPM

LI

N

SP

EE

D

, FT

/M

IN

FIR

ST

 LA

Y

ER