beautypg.com

Typical layout, Hydraulic system requirements – Ramsey Winch 20K POWERMASTER User Manual

Page 5

background image

3 OM-914209-0508-A

CONTROL VALVE

3 POSITION

4 WAY VALVE

(MOTOR SPOOL)

HIGH PRESSURE LINE

DUAL-A & B PORT CONTROL

WITH BRAKE RELEASE SHUTTLE

BRAKE

PORT

B

MOTOR

A

TYPICAL LAYOUT

LOW PRESSURE LINE

PUMP

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts, below, to properly match your hydraulic system to Linemaster 20K winch
performance. The charts consist of:

(1) Line pull (lb.) first layer vs. working pressure (PSI) and (2) Line speed, first layer (FPM) vs. gallons per

minute (GPM). Performance based on a motor displacement of 14.9 cubic inches with 30 GPM maximum
flow rate. Motor has (2) 1.062-12 SAE straight thread o-ring ports.

Note:

A motor spool (open center) directional control valve is required for brake operation.

PERFORMANCE CHARTS

BASED ON 14.9 CU IN/REV MOTOR

0

5000

10000

15000

20000

0

500

1000

1500

2000

2500

WORKING PRESSURE, PSI

LI

N

P

U

LL,

 LBS

FIR

ST

 LA

Y

ER

0

5

10

15

20

25

30

35

40

45

0

5

10

15

20

25

30

FLOW, GPM

LI

N

SP

EE

D

, FT

/M

IN

FIR

ST

 LA

Y

ER