ATTO Technology 2400C/R/D User Manual
Page 40

vii
ATTO Technology Inc. FibreBridge Installation and Operation Manual
DisplayEventLogFilter
Filters the display of data for specified subsystems and levels if
is enabled. Valid event log subsystem
entries are platform-dependent. For set commands, the final
parameter indicates whether or not events from the specified
subsystem and level are displayed.
Default: all all all
set DisplayEventLogFilter [subsystem | all] [level | all] [all
| none]
get DisplayEventLogFilter [subsystem | all] [level | all]
DisplayTraceLog
Displays the most recent page of trace log entries. The optional
parameter n is the number of lines to be displayed as a single
page with no user interaction. After the command has executed,
use +, - or = to scroll through the log. Type quit and press
Enter to exit the command.
DisplayTraceLog
DisplayTraceLogFilter
Filters the display of data for specific ports if
is enabled.
set DisplayTraceLogFilter [FC | SCSI | all] [fp | sb | all]
[none | chkcond | all]
get DisplayTraceLogFilter [FC | SCSI | all] [fp | sb | all]
DumpConfiguration
Displays the FibreBridge configuration.
DumpConfiguration
DumpEventLog
Dumps the entire contents of the event log to the ExpressNAV
Advanced page text box, RS-232 or Telnet session.
DumpEventLog
DumpTraceLog
Dumps the entire contents of the trace log to the ExpressNAV
Advanced page text box, RS-232 or Telnet session.
DumpTraceLog
EmailFromAddress
Configures the Email address that the FibreBridge uses to
communicate with the Email server. Full Email address is a fully
qualified Internet Email address, not more than 128 characters
long.
set EmailFromAddress [full email address]
get EmailFromAddress
EmailNotify
Regulates Email notification.
Default: disabled.
set EmailNotify [enabled | disabled]
get EmailNotify
EmailNotifyAddress
Configures notification addresses. Index is a number 1-5. Full
Email address is a fully qualified Internet Email address, not
more than 128 characters long. Warning level can be All,
Warning, Critical or None. None means no Emails are sent;
Critical means only critical severity events sends an Email;
Warning means only warnings and critical events send Email,
and All means all warnings and critical events warrant an
Email.
set EmailNotifyAddress [index] [full email address]
[warning level]
get EmailNotifyAddress
EmailPassword
Configures the password used to authenticate the login to the
SMTP Email server. The password must not be more than 64
characters. A password is not required if the Email server does
not require authentication.
set EmailPassword
Requires a SaveConfiguration command
EmailServerAddress
Configures the address of the server the FibreBridge must
contact in order to send out Email notifications.
set EmailServerAddress [IP address]
Requires a SaveConfiguration command
get EmailServerAddress
EmailUsername
Configures the user name used to authenticate the login to the
SMTP Email server. The user name must not be more than 128
characters. A user name is not required if the Email server does
not require authentication.
set EmailUsername
Requires a SaveConfiguration command
get EmailUsername
EthernetSpeed
Sets/displays the current speed of the Ethernet connection.
Choices are 10, 100, and Auto.
Default: auto
set EthernetSpeed [mp1] [ 10 | 100 | Auto ]
Requires a SaveConfiguration Restart command
get EthernetSpeed [mp1]
If auto enabled, returned value in parentheses indicates
current speed