Email messages provide error notification – ATTO Technology 2400C/R/D User Manual
Page 26
![background image](/manuals/35685/26/background.png)
21
ATTO Technology Inc. FibreBridge Installation and Operation Manual
Email messages provide error notification
Email notification allows the FibreBridge to send an
Email message to you, a network administrator or
other users when certain events occur. Serious error
messages are sent immediately, while messages for
less serious errors are sent every 15 minutes.
You may send Emails to up to five Email addresses
and designate which conditions prompt each Email
notification.
When an event occurs that has been designated as
requiring Email notification, the FibreBridge sends the
message; it cannot respond to a rejection by a server
for an invalid address. Ensure all Email addresses
typed in are valid.
Each Email is time stamped when it leaves as part of
the SMTP header information as shown in Exhibit 3.0-
5.
1
If you are not already in the ExpressNAV
interface, type the IP address of your
FibreBridge in a standard browser as found in
on page 27, click
Enter
Here, type in your user name and password,
and click
OK.
2
On the left hand menu, click
Remote Mgt.
3
The
Remote Management page appears.
4
Click on the
enabled radio button next to the
Email Notification heading.
5
Type in the sender address (Emails show this
name in the
From field).
6
Type in the SMTP Server IP address.
7
Type in the user name and password of your
SMTP Email account if your server requires it
8
Type in up to five Email addresses.
9
Choose
All, Warning, or Critical for each
Email address.
10 When all information is typed in, click
Submit.
Temperature
Warning
Yes
Yes
Unit’s internal temperature has increased to at or
within the unit’s maximum operating temperature
less the unit’s temperature warning offset or
decreased to at or within the unit’s minimum
operating temperature plus the unit’s temperature
warning offset.
Unit Attention
Info
No
Yes
A SCSI command discovers a unit attention
condition has occurred.
Unit Power On
Info
Yes
Yes
The unit has been powered up.
Voltage
Info
Yes
Yes
A monitored voltage level has increased or
decreased to within standard operating ranges.
Voltage
Critical
Yes
Yes
A monitored nominal voltage level has increased
or decreased beyond the percentages listed
below:
Level
...
VDDA
......
VDDB
..... .
VDDC
........
VDDD
.............
3.30V
.........
2.50V
........
1.50V
.........
1.35V
Low
.......
5%
..............
4%
............
5%
.........,..
4.5%
High
....
8%
............
5%
..... ....
5%
...........
5%
Voltage
Warning
Yes
Yes
A monitored nominal voltage level has increased
or decreased beyond the percentages listed
below:
Level
...
VDDA
......
VDDB
..... .
VDDC
........
VDDD
.............
3.30V
.........
2.50V
........
1.50V
.........
1.35V
Low
.......
3%
..............
3%
..........
3%
.........,..
3%
High
.....
5%
..........
3.5%
... ......
3%
...........
3%
Event
Severity
Level
Extended
Traps disabled
Extended
Traps enabled
Explanation