beautypg.com

Operation, Warning – Lincoln Electric IM10108 LTA 2.0-CW TELESCOPIC EXTRACTION ARM User Manual

Page 14

background image

B-2

OPERATION

B-2

PRODUCT COMBINATIONS

If the product is used in combination with other prod-
ucts or machines, the safety instructions in the docu-
mentation of these products also apply.

LTA 2.0-CW™

RISK OF FIRE

NEVER USE THE PRODUCT FOR:

• Extracting flammable, glowing or

burning particles or solids or liquids.

• Extracting of aggressive fumes (such

as hydrochloric acid) or sharp parti-
cles.

• Extracting dust particles which are released

when welding surfaces treated with primer.

• Smoking cigarettes, cigars, oiled tissues, and

other burning particles, objects, and acids.

WARNING

• Always use Personal Protective

Equipment (PPE) to avoid injury. This
also applies for persons who enter the
work area.

------------------------------------------------------------------------

WARNING

CONTROLS

The LTA 2.0-CW™ is provided with a handle for easy
positioning and a throttle valve for adjustment of the
airflow. All movement of the arm is controlled from the
hood.

A. Rotary knobs for adjustment of throttle valve.
B. Handle for positioning of the extraction arm and

hood.

A

B

• Using the handle (B), position the hood of the extrac-

tion arm in the desired position at approximately 6-
20 inches (15-50 cm) from the source of fume.

NOTE: Retraction movement must happen slowly to

allow counterweight to descend.

• Open the throttle valve (A).

• Turn on the connected extraction fan; refer to the

corresponding manual.

• Start welding.

• If desired, adjust the airflow by turning the rotary

knob of the throttle valve (A).

NOTE: If an automatic damper system is part of the

assembly, keep the manual damper open at
all times.

• Turn off the connected extraction fan approx. 20 sec-

onds after finishing welding; refer to the correspond-
ing manual.

FIGURE B.1 - CONTROLS