beautypg.com

Installation, Caution – Lincoln Electric IM10108 LTA 2.0-CW TELESCOPIC EXTRACTION ARM User Manual

Page 11

background image

A-4

INSTALLATION

LTA 2.0-CW™

A-4

ATTACHING THE COUNTERWEIGHT
CASING

• Slide the counterweight casing (C) over the counter-

weight.

• Using a 13mm wrench, fasten the casing to the wall

mounting bracket (A) using 2 bolts M8x10 and 2 lock
washers M8 (B).

• Securely tighten bolts.

ATTACHING THE ROPE

• Pull the arm to the longest position.
• Guide the rope through the rotating hinge (D) and

over the pulley (C), the counterweight pulley (B) and
the other small pulley (A).

• Keep the counterweight in the highest position,

which means just below the small pulleys. Securely
fasten the rope to the counterweight by tying a knot
(E). The rope should be threaded through the hole
in the counterweight pulley. The knot must be large
enough so the rope cannot slip back through the
hole.

A B C

D

E

CAUTION

• Tying the counterweight too low will affect the

reach of the extraction arm.

B

C

A