Certifications internal connections and functions, Installation – Warner Electric CBPC-3590 User Manual
Page 4
4 Warner Electric • 800-825-9050
P-921-1 • 819-0526
9 Pin Brad Harrison for clutch, brake, power and
switching.
Mating connector for wiring to power, load, and
switching circuits:
Brad Harrison
# 309002A01F030 with 3 foot pigtails
# 309002A01F060 with 6 foot pigtails
# 309002A01F120 with 12 foot pigtails
Certifications
Internal Connections and Functions
Internal Wiring Connections: via plug on Molex
type terminal blocks
Internal Switches: SW1: Set-up/Normal switch
used for initial set up and calibration of control
Keypad functions: 0 through 9 numeral inputs
when in programming mode
Start and Stop functions:
Note: Start key also functions as the home set
up key in set-up mode.
Up, Down and right arrow keys for scrolling and
selecting data
Edit Key: Run/PGM Key for entering set up
modes
Reset/Clear Key: For resetting variables or
clearing data in programming mode
Fault Relay: In the event of a fault, relay contacts
via terminal strip for external customer
connections .
Contacts: Rated at 1 Amp, 120 VAC resistive load
Fault Conditions: Low voltage, feedback too fast,
process time fully utilized
Clutch-Brake Output Level: Programmable via
display and keypad
Output Frequency: Programmable via display and
keypad
Communications: RS-485 communications port
via terminal strip
Optional OEX function card: An optional OEX
function card can be added for special
applications that require reduced build-up times
of the clutch or brake magnets.
Input/Outputs: Additional programmable inputs
and outputs available but not active for other
specific functions and typically are not used when
this controller is used for replacing the
CBC1500-AHFC or being used in pusher type
applications . Consult factory for further
information .
Control Part Number: 6051-448-002 CBPC-3590
Control
Encoder Part Number: 6060-101-061 Encoder,
600 PPR with marker pulse and cable
Installation
Replacing CBC1500-AHFC Control with
CBPC-3590 Control
q
1. Insure that power is turned off and
disconnected to the CBC1500-AHFC control.
q
2 . Disconnect both the encoder cable
connector and the main power/clutch-brake
wire connector from the plugs on the control-
ler .
q
3 . Remove the 4 bolts or nuts fastening the
controller to the isolation mounts on the
machine frame .
q
4 . Remove the controller and set aside .
q
5. Install the CBPC-3590 controller on the
isolation mounts and reattach with either the
bolts or nuts depending on what was originally
used. Make sure bolts or nuts are securely
tightened .
®