beautypg.com

Introduction, About qualiphy, About qphy-10gbase-t option – Teledyne LeCroy QPHY-10GBase-T User Manual

Page 5: Required equipment

background image

QPHY-10GBASE-T Operator’s Manual

Introduction

About QualiPHY

QualiPHY is a highly automated compliance test software meant to help you develop and
validate the PHY (physical-electrical) layer of a device, in accordance with the official
documents published by the applicable standards organizations and special interest groups
(SIGs). You can additionally set custom variables and limits to test compliance to internal
standards.

QualiPHY is composed of a “framework” application that enables the configuration and control
of separate tests for each standard through a common user interface. Features include:

Multiple Data Source Capability: Connect to your X-Stream oscilloscope via LAN or

other interfaces.

User-Defined Test Limits: Parameter interconnect losses can be factored into the

parametric results.

Flexible Test Results Reporting that includes XML Test Record Generation.

Understand a device performance distribution, or obtain process related information from
the devices under test.

About QPHY-10GBASE-T Option

QPHY-10GBASE-T is an automated test package performing all the normative, real-time
oscilloscope tests for transmitter and return loss sources in accordance with IEEE 802.3-2008.

The transmitter testing is performed using any Teledyne LeCroy WaveMaster 8 Zi-A, LabMaster
9 Zi-A or LabMaster 10 Zi oscilloscope installed with QualiPHY version 7.4 or higher. The fixture
kit TF-10GBASE-T is available for breaking out signals from DUT. All tests in section 55.5.3 are
performed by the software.

The 10GBASE-T MDI return loss test is performed using a Teledyne LeCroy SPARQ Series
Network Analyzer. The TF-10GBASE-T fixture kit includes a calibration board and balun for the
calibration of the analyzer, and a balun for creating a differential signal.

Required Equipment

See the respective test sections of this manual for required equipment.

For the most complete and up-to-date lists, see the IEEE 802.3 Ethernet Working Group
website: www.ieee802.org/3/

923663 Rev A

1