Operation...

The air regulator knob can be used as an air throttle, if there are

no other means of regulating air. Turn the air regulator knob all the

way to highest position for maximum power.

The air regulator can be used to adjust torque to the ap prox i mate

tightness of a known fastener.

To set the tool to de sired torque, select a nut or screw of known

tight ness of the same size, thread pitch and thread con di tion as

those on the job. Turn air reg u la tor to low position, apply wrench

to nut and gradually increase pow er (turn regulator to admit more

air) until nut moves slightly in the di rec tion it was originally set. The

tool is now set to du pli cate that tight ness - note reg u la tor setting

for future use. When tight en ing nuts not requiring critical torque

values, run nut up flush and then tighten an additional one-quarter

to one-half turn (slight ad di tion al turning is necessary if gaskets

are being clamped). For additional power needed on dis as sem bly

work, turn regulator to its fully open position. This im pact wrench

is rated at 1/2" USS bolt size. Rating must be down graded for

spring U bolts, tie bolts, long cap screws, double depth nuts, badly

rusted conditions and spring fas ten ers, as they absorb much of the

impact power. When possible, clamp or wedge the bolt to prevent

springback.

Soak rusted nuts in pen e trat ing oil and break rust seal before

removing with im pact wrench. If nut does not start to move in three

to five sec onds, use a larger size impact wrench. Do not use impact

wrench be yond rated ca pac i ty, as this will dras ti cal ly reduce tool

life.

The forward/reverse lever is used to change the rotation of the tool.

When the lever is moved to the right, the tool is in a forward or right

hand rotation. When the lever is moved to the left, the ro ta tion is

reverse or left hand.

noTe: Actual torque on a fastener is directly related to joint

hardness, tool speed, condition of socket and the time the tool is

allowed to impact.

Use the simplest possible tool-to-socket hook up. Every connection

absorbs energy and reduces power.

Air Supply...

Tools of this class operate on a wide range of air pres sures. It is

recommended that air pres sure of these tools mea sures 90 PSI at the

tool while running free. Higher pres sure (over 90 psig; 6.2 bar) raises

per for mance beyond the rated capacity of the tool which will short en

tool life be cause of faster wear and could cause injury.
Always use clean, dry air. Dust, corrosive fumes and/or water in the air

line will cause damage to the tool. Drain the air tank daily. Clean the

air inlet filter screen on at least a weekly schedule. The rec om mend ed

hookup pro ce dure can be viewed in figure 1.
The air inlet used for connecting air supply, has standard 1/4" NPT.

Line pressure should be increased to compensate for unusually long

air hoses (over 25 feet). Minimum hose diameter should be 3/8" I.D.

and fittings should have the same inside dimensions and be tightly

secured.

Lubrication...

Lubricate the air motor daily with quality air tool oil. If no air line oiler

is used, run 1/2 ounce of air tool oil through the tool by squirting oil

into the tool's air inlet or into the nearest connection to the air inlet,

reconnecting air supply, and then running tool. Do not use more than

1/2 ounce of oil, as overfilling will reduce the performance of the

tool.

Troubleshooting...

Other factors outside the tool may cause loss of power or erratic

action. Reduced compressor output, excessive drain on the air line,

moisture or restrictions in air pipes or the use of hose connections

of improper size or poor conditions may reduce air supply. Grit or

gum deposits in the tool may cut power and may be corrected by

cleaning the air strainer and flushing out the tool with gum solvent

oil or an equal mixture of SAE #10 and kerosene. If outside conditions

are in order, disconnect tool from hose and take tool to your nearest

authorized service center.

Limited Warranty...

SUNEX INTERNATIONAL, INC. WARRANTS TO ITS CUSTOMERS THAT THE COMPANY’S SUNEX TOOLS® BRANDED PRODUCTS ARE

FREE FROM DEFECTS IN WORKMANSHIP AND MATERIALS.

Sunex International, Inc. will repair or replace its Sunex Tools® branded products which fail to give satisfactory service due to defective workmanship or materials, based upon the

terms and conditions of the following described warranty plans attributed to that specific product. This product carries a ONE-YEAR warranty. During this warranty period, Sunex

Tools® will repair or replace at our option any part or unit which proves to be defective in material or workmanship.

Other important warranty information...

This warranty does not cover damage to equipment or tools arising from alteration, abuse, misuse, damage and does not cover any repairs or replacement made by anyone other

than Sunex Tools® or its authorized warranty service centers. The foregoing obligation is Sunex Tools® sole liability under this or any implied warranty and under no circumstances

shall we be liable for any incidental or consequential damages.

Note: Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Return equipment or

parts to Sunex Tools®, or an authorized warranty service center, transportation prepaid. Be certain to include your name and address, evidence of the purchase date, and description

of the suspected defect.

If you have any questions about warranty service, please write to Sunex Tools®. This warranty gives you specific legal rights and you may also have other rights which vary from

state to state. Repair kits and replacement parts are available for many of Sunex Tools® products regardless of whether or not the product is still covered by a warranty plan.
SHIPPINg ADDRESS: Sunex Tools • 315 Hawkins Rd. • Travelers Rest, SC 29690

MAILINg ADDRESS: Sunex Tools • P.O. Box 1233 • Travelers Rest, SC 29690

Operating Instructions • Warning Information • Parts Break down

Drain Daily

Regulator

Oiler

Quick Coupler

Leader

Hose

Nipple

Do Not In stall

Quick Coupling

Here

Nipple

Filter

Air Supply

Whip Hose

This manual is related to the following products: